Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Michigan State University |
---|---|
Assessment Year | 2025 |
Principal Product | Wood |
NAICS | 321113 - Sawmills |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $10,000,000-$50,000,000 |
# of Employees | 400 |
Plant Area (Sq.Ft.) | 165,000 |
Annual Production | 17,000,000 Units |
Production Hrs. Annual | 4,264 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $395,098 | 4,927,832 | kWh | $0.08 |
Electricity Demand | $217,201 | 27,807 | kW-months/year | $7.81 |
Electricity Fees | $13,737 | - | $ | - |
Natural Gas | $107,806 | 19,426 | MMBtu | $5.55 |
Fuel Oil #1 | $19,255 | 931 | MMBtu | $20.67 |
Other Gas | $2,889 | 1 | MMBtu | $2,889.00 |
TOTAL ENERGY COSTS | $755,986 | |||
RECOMMENDED SAVINGS* | $30,406 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #1 | Ancillary Material Cost | Electricity Usage | Electricity Demand | Fuel Oil #1 | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT |
Savings: $25,925 Cost: $65,000 |
$(-1,076) | (-13,451) | $(-504) | (-65) | $19,255 | 931 | $8,250 | - |
$(-1,076) (-13,451) kWh |
$(-504) (-65) kW-months/year |
$19,255 931 MMBtu |
$8,250 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,851 Cost: $577 |
$2,514 | 31,431 | $336 | 43 | - | - | - | - |
$2,514 31,431 kWh |
$336 43 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,188 Cost: $3,637 |
$859 | 10,732 | $330 | 42 | - | - | - | - |
$859 10,732 kWh |
$330 42 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $442 Cost: $1,277 |
$323 | 4,032 | $119 | 15 | - | - | - | - |
$323 4,032 kWh |
$119 15 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $30,406 Cost: $70,491 |
$2,619 | 32,744 | $281 | 36 | $19,255 | 931 | $8,250 | - | $2,619 32,744 kWh |
$281 36 kW-months/year |
$19,255 931 MMBtu |
$8,250 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #1 | Ancillary Material Cost | Electricity Usage | Electricity Demand | Fuel Oil #1 | Ancillary Material Cost |