IAC logo
IAC Assessment: MUCM25
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MUCM25
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Michigan State University
Assessment Year 2025
Principal Product Medical Office
NAICS 621111 - Offices of Physicians (except Mental Health Specialists)
SIC 8011 - Offices & Clinics Of Medical Doctors
Sales <$500,000
# of Employees 30
Plant Area (Sq.Ft.) 11,500
Annual Production 1 Units
Production Hrs. Annual 2,912
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $5,362 69,840 kWh $0.08
Electricity Demand $4,594 207 kW-months/year $22.19
Electricity Fees $2,476 - $ -
Natural Gas $1,821 201 MMBtu $9.05
Other Gas $109 1 MMBtu $109.23
TOTAL ENERGY COSTS $14,362
RECOMMENDED SAVINGS* $4,282 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$182
Cost:
-
$55 693 $127 6 - - $55
693
kWh
$127
6
kW-months/year
-
-
MMBtu
02: 2.7134 USE PHOTOCELL CONTROLS Savings:
$92
Cost:
$401
$43 543 $49 2 - - $43
543
kWh
$49
2
kW-months/year
-
-
MMBtu
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$350
Cost:
$1,478
$163 2,043 $187 8 - - $163
2,043
kWh
$187
8
kW-months/year
-
-
MMBtu
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$43
Cost:
-
$16 203 $27 1 - - $16
203
kWh
$27
1
kW-months/year
-
-
MMBtu
05: 2.7291 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS Savings:
$359
Cost:
-
$51 637 - - $308 34 $51
637
kWh
-
-
kW-months/year
$308
34
MMBtu
06: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$193
Cost:
$307
$140 1,744 $53 2 - - $140
1,744
kWh
$53
2
kW-months/year
-
-
MMBtu
07: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$1,443
Cost:
$13,685
$188 2,356 $215 10 $1,039 115 $188
2,356
kWh
$215
10
kW-months/year
$1,039
115
MMBtu
08: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$1,620
Cost:
$12,320
$877 10,967 $743 34 - - $877
10,967
kWh
$743
34
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$4,282
Cost:
$28,191
$1,535 19,185 $1,401 63 $1,347 149 $1,535
19,185
kWh
$1,401
63
kW-months/year
$1,347
149
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas