Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Michigan State University
Assessment Year 2025
Principal Product HVAC Equipment
NAICS 238220 - Plumbing, Heating, and Air-Conditioning Contractors
SIC 1711 - Plumbing, Heating, Air-conditioning
Sales $10,000,000-$50,000,000
# of Employees 175
Plant Area (Sq.Ft.) 30,000
Annual Production 3,700 Units
Production Hrs. Annual 3,120
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $31,238 220,588 kWh $0.14
Electricity Fees $7,225 - $ -
Natural Gas $15,224 1,491 MMBtu $10.21
Other Gas $1,353 1 MMBtu $1,353.00
TOTAL ENERGY COSTS $55,040
RECOMMENDED SAVINGS* $11,738 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$6,696
Cost:
$11,326
$(-150) (-1,053) $6,846 670 $(-150)
(-1,053)
kWh
$6,846
670
MMBtu
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$2,532
Cost:
-
$1,536 10,818 $996 97 $1,536
10,818
kWh
$996
97
MMBtu
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$206
Cost:
-
$206 1,466 - - $206
1,466
kWh
-
-
MMBtu
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$930
Cost:
-
$930 6,552 - - $930
6,552
kWh
-
-
MMBtu
05: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$720
Cost:
-
$720 5,070 - - $720
5,070
kWh
-
-
MMBtu
06: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$100
Cost:
$438
$100 702 - - $100
702
kWh
-
-
MMBtu
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$123
Cost:
$468
$123 867 - - $123
867
kWh
-
-
MMBtu
08: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$306
Cost:
$217
- - $306 29 -
-
kWh
$306
29
MMBtu
09: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$125
Cost:
$215
$48 341 $76 7 $48
341
kWh
$76
7
MMBtu
TOTAL RECOMMENDED Savings:
$11,738
Cost:
$12,664
$3,514 24,762 $8,224 803 $3,514
24,762
kWh
$8,224
803
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas