Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Missouri-Columbia |
---|---|
Assessment Year | 2009 |
Principal Product | chemicals |
NAICS | 325110 - Petrochemical Manufacturing |
SIC | 2869 - Industrial Organic Chemicals, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 120 |
Plant Area (Sq.Ft.) | 150,000 |
Annual Production | 500,000 Tons |
Production Hrs. Annual | 6,000 |
Location (State) | MO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $167,500 | 2,431,000 | kWh | $0.07 |
Other Energy | $324,000 | 27,673 | MMBtu | $11.71 |
TOTAL ENERGY COSTS | $491,500 | |||
RECOMMENDED SAVINGS* | $589,810 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $543,300 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,975 Cost: $4,500 |
$1,405 | 23,232 | $570 | 47 | - | - | - | - | - | - |
$1,405 23,232 kWh |
$570 47 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $19,660 Cost: $18,000 |
- | - | - | - | $19,660 | 1,106 | - | - | - | - |
- - kWh |
- - kW-months/year |
$19,660 1,106 MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $905 Cost: $905 |
$905 | 13,122 | - | - | - | - | - | - | - | - |
$905 13,122 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $23,970 Cost: $214,200 |
$19,458 | 282,000 | $4,512 | 564 | - | - | - | - | - | - |
$19,458 282,000 kWh |
$4,512 564 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.512 CONDENSE OPERATION INTO ONE BUILDING |
Savings: $543,300 Cost: $150,000 |
$155,000 | 2,248,000 | - | - | $228,000 | 19,495 | $142,000 | - | $18,300 | - |
$155,000 2,248,000 kWh |
- - kW-months/year |
$228,000 19,495 MMBtu |
$142,000 - Tgal |
$18,300 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $589,810 Cost: $387,605 |
$176,768 | 2,566,354 | $5,082 | 611 | $247,660 | 20,601 | $142,000 | - | $18,300 | - | $176,768 2,566,354 kWh |
$5,082 611 kW-months/year |
$247,660 20,601 MMBtu |
$142,000 - Tgal |
$18,300 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $543,300 Cost: $150,000 |
$155,000 | 2,248,000 | - | - | $228,000 | 19,495 | $142,000 | - | $18,300 | - | $155,000 2,248,000 kWh |
- - kW-months/year |
$228,000 19,495 MMBtu |
$142,000 - Tgal |
$18,300 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption |