IAC logo
IAC Assessment: MZ0085
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MZ0085
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Missouri-Columbia
Assessment Year 2012
Principal Product zinc and plated fixtures
NAICS 332812 - Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers
SIC 3479 - Metal Coating And Allied Services
Sales $50,000,000-$100,000,000
# of Employees 65
Plant Area (Sq.Ft.) 110,000
Annual Production 300 Tons
Production Hrs. Annual 4,950
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $84,441 1,472,920 kWh $0.06
Electricity Demand $22,028 4,901 kW-months/year $4.49
Natural Gas $406,039 52,494 MMBtu $7.73
TOTAL ENERGY COSTS $512,508
RECOMMENDED SAVINGS* $156,643 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $154,995
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,648
Cost:
$820
$1,388 23,137 $260 58 - - $1,388
23,137
kWh
$260
58
kW-months/year
-
-
MMBtu
02: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC Savings:
$79,573
Cost:
$6,500
- - - - $79,573 10,268 -
-
kWh
-
-
kW-months/year
$79,573
10,268
MMBtu
03: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC Savings:
$72,621
Cost:
$8,500
- - - - $72,621 7,370 -
-
kWh
-
-
kW-months/year
$72,621
7,370
MMBtu
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,801
Cost:
$8,200
$2,370 39,501 $431 96 - - $2,370
39,501
kWh
$431
96
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$156,643
Cost:
$24,020
$3,758 62,638 $691 154 $152,194 17,638 $3,758
62,638
kWh
$691
154
kW-months/year
$152,194
17,638
MMBtu
TOTAL IMPLEMENTED Savings:
$154,995
Cost:
$23,200
$2,370 39,501 $431 96 $152,194 17,638 $2,370
39,501
kWh
$431
96
kW-months/year
$152,194
17,638
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas