Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Missouri-Columbia
Assessment Year 2014
Principal Product plastic bags
NAICS 326111 - Plastics Bag and Pouch Manufacturing
SIC 2673 - Bags: Plastics, Laminated, & Coated
Sales $10,000,000-$50,000,000
# of Employees 142
Plant Area (Sq.Ft.) 130,000
Annual Production 189,431,247 Pieces
Production Hrs. Annual 8,544
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $558,610 11,223,956 kWh $0.05
Electricity Demand $41,474 20,136 kW-months/year $2.06
Natural Gas $10,051 3,690 MMBtu $2.72
TOTAL ENERGY COSTS $610,135
RECOMMENDED SAVINGS* $33,103 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $20,537
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$871
Cost:
$360
$871 17,419 - - $871
17,419
kWh
-
-
kW-months/year
02: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$63
Cost:
$235
$63 1,269 - - $63
1,269
kWh
-
-
kW-months/year
03: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$63
Cost:
$235
$63 1,269 - - $63
1,269
kWh
-
-
kW-months/year
04: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$423
Cost:
$470
$423 8,459 - - $423
8,459
kWh
-
-
kW-months/year
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$10,562
Cost:
$42,645
$9,850 196,999 $712 345 $9,850
196,999
kWh
$712
345
kW-months/year
06: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE Savings:
$1,184
Cost:
$600
$1,184 23,680 - - $1,184
23,680
kWh
-
-
kW-months/year
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$9,950
Cost:
$5,290
$8,427 168,538 $1,523 739 $8,427
168,538
kWh
$1,523
739
kW-months/year
08: 2.2511 INSULATE BARE EQUIPMENT Savings:
$2,616
Cost:
$2,613
$2,616 52,315 - - $2,616
52,315
kWh
-
-
kW-months/year
09: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$4,212
Cost:
$420
$3,982 79,631 $230 112 $3,982
79,631
kWh
$230
112
kW-months/year
10: 2.6127 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT Savings:
$3,158
Cost:
$250
$2,985 59,708 $173 84 $2,985
59,708
kWh
$173
84
kW-months/year
TOTAL RECOMMENDED Savings:
$33,103
Cost:
$53,118
$30,465 609,287 $2,638 1,280 $30,465
609,287
kWh
$2,638
1,280
kW-months/year
TOTAL IMPLEMENTED Savings:
$20,537
Cost:
$45,215
$19,422 388,434 $1,115 541 $19,422
388,434
kWh
$1,115
541
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand