IAC logo
IAC Assessment: MZ0174
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MZ0174
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Missouri-Columbia
Assessment Year 2015
Principal Product store furnatures and fixtures
NAICS 337215 - Showcase, Partition, Shelving, and Locker Manufacturing
SIC 2541 - Wood Partitions And Fixtures
Sales $10,000,000-$50,000,000
# of Employees 200
Plant Area (Sq.Ft.) 96,000
Annual Production 200,000 Pieces
Production Hrs. Annual 8,600
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $216,535 3,070,061 kWh $0.07
Electricity Demand $26,439 9,968 kW-months/year $2.65
Natural Gas $18,693 2,805 MMBtu $6.66
TOTAL ENERGY COSTS $261,667
RECOMMENDED SAVINGS* $72,558 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$28,665
Cost:
$105,525
$27,235 386,140 $1,430 539 - - $27,235
386,140
kWh
$1,430
539
kW-months/year
-
-
MMBtu
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$17,740
Cost:
$1,500
$17,740 251,550 - - - - $17,740
251,550
kWh
-
-
kW-months/year
-
-
MMBtu
03: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$1,335
Cost:
-
$1,335 18,926 - - - - $1,335
18,926
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$6,584
Cost:
$6,500
$6,255 88,682 $329 124 - - $6,255
88,682
kWh
$329
124
kW-months/year
-
-
MMBtu
05: 3.1161 ELIMINATE/REDUCE AN OPERATION Savings:
$736
Cost:
-
$691 9,804 $45 17 - - $691
9,804
kWh
$45
17
kW-months/year
-
-
MMBtu
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$13,904
Cost:
$1,210
$13,212 187,322 $692 261 - - $13,212
187,322
kWh
$692
261
kW-months/year
-
-
MMBtu
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$2,409
Cost:
$2,500
$2,245 31,824 $164 62 - - $2,245
31,824
kWh
$164
62
kW-months/year
-
-
MMBtu
08: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$1,185
Cost:
-
$763 10,814 $42 16 $380 57 $763
10,814
kWh
$42
16
kW-months/year
$380
57
MMBtu
TOTAL RECOMMENDED Savings:
$72,558
Cost:
$117,235
$69,476 985,062 $2,702 1,019 $380 57 $69,476
985,062
kWh
$2,702
1,019
kW-months/year
$380
57
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas