Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Missouri-Columbia |
---|---|
Assessment Year | 2017 |
Principal Product | Aeration water treatment system |
NAICS | 333413 - Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing |
SIC | 3564 - Blowers And Fans |
Sales | $50,000,000-$100,000,000 |
# of Employees | 225 |
Plant Area (Sq.Ft.) | 56,000 |
Annual Production | 100,000 Units |
Production Hrs. Annual | 7,776 |
Location (State) | MO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $178,171 | 3,125,990 | kWh | $0.06 |
Electricity Demand | $100,374 | 6,666 | kW-months/year | $15.06 |
Natural Gas | $17,934 | 1,907 | MMBtu | $9.40 |
TOTAL ENERGY COSTS | $296,479 | |||
RECOMMENDED SAVINGS* | $23,309 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $21,413 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Usage | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Usage | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $15,978 Cost: $27,450 |
$10,651 | 186,857 | $4,351 | 288 | - | - | - | - | $976 | - |
$10,651 186,857 kWh |
$4,351 288 kW-months/year |
- - MMBtu |
- - Tgal |
$976 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,308 Cost: - |
$1,308 | 22,939 | - | - | - | - | - | - | - | - |
$1,308 22,939 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.4151 MINIMIZE WATER USAGE |
Savings: $199 Cost: $30 |
- | - | - | - | - | - | $199 | 20 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$199 20 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $1,896 Cost: $6,500 |
$1,896 | 33,278 | - | - | - | - | - | - | - | - |
$1,896 33,278 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $3,927 Cost: $1,050 |
- | - | - | - | $3,927 | 418 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,927 418 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $23,309 Cost: $35,030 |
$13,855 | 243,074 | $4,351 | 288 | $3,927 | 418 | $199 | 20 | $976 | - | $13,855 243,074 kWh |
$4,351 288 kW-months/year |
$3,927 418 MMBtu |
$199 20 Tgal |
$976 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $21,413 Cost: $28,530 |
$11,959 | 209,796 | $4,351 | 288 | $3,927 | 418 | $199 | 20 | $976 | - | $11,959 209,796 kWh |
$4,351 288 kW-months/year |
$3,927 418 MMBtu |
$199 20 Tgal |
$976 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Usage | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Usage | One-time Revenue or Avoided Cost |