Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Missouri-Columbia |
---|---|
Assessment Year | 2019 |
Principal Product | lawn and garden power equipment |
NAICS | 333112 - Lawn and Garden Tractor and Home Lawn and Garden Equipment Manufacturing |
SIC | 3524 - Lawn And Garden Equipment |
Sales | $10,000,000-$50,000,000 |
# of Employees | 110 |
Plant Area (Sq.Ft.) | 112,000 |
Annual Production | 146,000 Pieces |
Production Hrs. Annual | 1,664 |
Location (State) | MO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $87,699 | 915,600 | kWh | $0.10 |
Electricity Demand | $17,047 | 5,196 | kW-months/year | $3.28 |
Natural Gas | $35,655 | 6,919 | MMBtu | $5.15 |
TOTAL ENERGY COSTS | $140,401 | |||
RECOMMENDED SAVINGS* | $25,451 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,001 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $630 Cost: $1,240 |
$504 | 5,301 | $126 | 38 | - | - | - | - |
$504 5,301 kWh |
$126 38 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,437 Cost: $17,755 |
$5,213 | 54,869 | $1,154 | 351 | - | - | $4,070 | - |
$5,213 54,869 kWh |
$1,154 351 kW-months/year |
- - MMBtu |
$4,070 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $343 Cost: - |
$274 | 2,880 | $69 | 21 | - | - | - | - |
$274 2,880 kWh |
$69 21 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $1,435 Cost: $5,500 |
- | - | - | - | $1,435 | 279 | - | - |
- - kWh |
- - kW-months/year |
$1,435 279 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $221 Cost: - |
$177 | 1,863 | $44 | 13 | - | - | - | - |
$177 1,863 kWh |
$44 13 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $12,385 Cost: $4,900 |
$12,385 | 130,368 | - | - | - | - | - | - |
$12,385 130,368 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $25,451 Cost: $29,395 |
$18,553 | 195,281 | $1,393 | 423 | $1,435 | 279 | $4,070 | - | $18,553 195,281 kWh |
$1,393 423 kW-months/year |
$1,435 279 MMBtu |
$4,070 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,001 Cost: $17,755 |
$5,664 | 59,612 | $1,267 | 385 | - | - | $4,070 | - | $5,664 59,612 kWh |
$1,267 385 kW-months/year |
- - MMBtu |
$4,070 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost |