Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Missouri-Columbia |
---|---|
Assessment Year | 2019 |
Principal Product | Cookies |
NAICS | 311821 - Cookie and Cracker Manufacturing |
SIC | 2052 - Cookies And Crackers |
Sales | $100,000,000-$500,000,000 |
# of Employees | 700 |
Plant Area (Sq.Ft.) | 400,000 |
Annual Production | 232,000,000 Pounds |
Production Hrs. Annual | 6,840 |
Location (State) | IA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $798,465 | 18,536,800 | kWh | $0.04 |
Electricity Demand | $664,704 | 35,154 | kW-months/year | $18.91 |
Natural Gas | $1,013,333 | 259,216 | MMBtu | $3.91 |
TOTAL ENERGY COSTS | $2,568,060 | |||
RECOMMENDED SAVINGS* | $173,376 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $134,845 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,394 Cost: $440 |
$787 | 18,304 | $607 | 32 | - | - | - | - | - | - |
$787 18,304 kWh |
$607 32 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $28,719 Cost: $50,000 |
- | - | - | - | $28,719 | 7,345 | - | - | - | - |
- - kWh |
- - kW-months/year |
$28,719 7,345 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,416 Cost: $4,211 |
$1,883 | 43,800 | $2,269 | 120 | - | - | - | - | $264 | - |
$1,883 43,800 kWh |
$2,269 120 kW-months/year |
- - MMBtu |
- - Tgal |
$264 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,650 Cost: $2,700 |
$1,650 | 38,368 | - | - | - | - | - | - | - | - |
$1,650 38,368 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $8,418 Cost: $1,920 |
$2,721 | 63,284 | $2,099 | 111 | - | - | - | - | $3,598 | - |
$2,721 63,284 kWh |
$2,099 111 kW-months/year |
- - MMBtu |
- - Tgal |
$3,598 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $55,889 Cost: $160 |
- | - | - | - | - | - | $55,889 | 9,020 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$55,889 9,020 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $70,665 Cost: $233,814 |
$16,423 | 373,248 | $13,925 | 648 | $40,317 | 10,311 | - | - | - | - |
$16,423 373,248 kWh |
$13,925 648 kW-months/year |
$40,317 10,311 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,816 Cost: $3,021 |
$1,816 | 42,227 | - | - | - | - | - | - | - | - |
$1,816 42,227 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.1135 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY |
Savings: $409 Cost: $1,200 |
- | - | - | - | $409 | 105 | - | - | - | - |
- - kWh |
- - kW-months/year |
$409 105 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $173,376 Cost: $297,466 |
$25,280 | 579,231 | $18,900 | 911 | $69,445 | 17,761 | $55,889 | 9,020 | $3,862 | - | $25,280 579,231 kWh |
$18,900 911 kW-months/year |
$69,445 17,761 MMBtu |
$55,889 9,020 Tgal |
$3,862 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $134,845 Cost: $245,106 |
$21,772 | 497,643 | $16,194 | 768 | $40,726 | 10,416 | $55,889 | 9,020 | $264 | - | $21,772 497,643 kWh |
$16,194 768 kW-months/year |
$40,726 10,416 MMBtu |
$55,889 9,020 Tgal |
$264 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | One-time Revenue or Avoided Cost |