Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Missouri-Columbia |
---|---|
Assessment Year | 2021 |
Principal Product | Human edible poultry products & Protein ingredients for animal feeds |
NAICS | 311613 - Rendering and Meat Byproduct Processing |
SIC | 2077 - Animal And Marine Fats And Oils |
Sales | $100,000,000-$500,000,000 |
# of Employees | 790 |
Plant Area (Sq.Ft.) | 370,000 |
Annual Production | 1,000,000,000 Pounds |
Production Hrs. Annual | 6,240 |
Location (State) | MO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,970,607 | 58,816,318 | kWh | $0.05 |
Electricity Demand | $1,350,393 | 109,922 | kW-months/year | $12.29 |
Natural Gas | $3,335,372 | 2,627,054 | MMBtu | $1.27 |
TOTAL ENERGY COSTS | $7,656,372 | |||
RECOMMENDED SAVINGS* | $839,975 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $444,974 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $65,174 Cost: $960 |
- | - | - | - | $65,174 | 29,356 | - | - |
- - kWh |
- - kW-months/year |
$65,174 29,356 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $8,714 Cost: $960 |
$5,549 | 108,806 | $3,165 | 258 | - | - | - | - |
$5,549 108,806 kWh |
$3,165 258 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $41,876 Cost: $42,513 |
$41,876 | 812,103 | - | - | - | - | - | - |
$41,876 812,103 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $11,649 Cost: $4,200 |
$7,960 | 156,079 | $3,689 | 300 | - | - | - | - |
$7,960 156,079 kWh |
$3,689 300 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $4,736 Cost: $4,920 |
$3,016 | 59,128 | $1,720 | 140 | - | - | - | - |
$3,016 59,128 kWh |
$1,720 140 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3192 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS |
Savings: $353,125 Cost: $770,000 |
$184,540 | 3,618,435 | $182,752 | 14,870 | $(-4,167) | (-13,023) | $(-10,000) | - |
$184,540 3,618,435 kWh |
$182,752 14,870 kW-months/year |
$(-4,167) (-13,023) MMBtu |
$(-10,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $354,701 Cost: $442,138 |
- | - | $354,701 | 28,861 | - | - | - | - |
- - kWh |
$354,701 28,861 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $839,975 Cost: $1,265,691 |
$242,941 | 4,754,551 | $546,027 | 44,429 | $61,007 | 16,333 | $(-10,000) | - | $242,941 4,754,551 kWh |
$546,027 44,429 kW-months/year |
$61,007 16,333 MMBtu |
$(-10,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $444,974 Cost: $453,178 |
$16,525 | 324,013 | $363,275 | 29,559 | $65,174 | 29,356 | - | - | $16,525 324,013 kWh |
$363,275 29,559 kW-months/year |
$65,174 29,356 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost |