Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Missouri-Columbia |
---|---|
Assessment Year | 2022 |
Principal Product | lead acid batteries |
NAICS | 335911 - Storage Battery Manufacturing |
SIC | 3691 - Storage Batteries |
Sales | $100,000,000-$500,000,000 |
# of Employees | 495 |
Plant Area (Sq.Ft.) | 504,400 |
Annual Production | 63,876,869 Pounds |
Production Hrs. Annual | 6,864 |
Location (State) | MO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,387,309 | 54,865,902 | kWh | $0.04 |
Electricity Demand | $1,062,735 | 101,312 | kW-months/year | $10.49 |
Natural Gas | $331,584 | 177,721 | MMBtu | $1.87 |
TOTAL ENERGY COSTS | $4,092,273 | |||
RECOMMENDED SAVINGS* | $759,848 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $170,570 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Water Disposal | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $23,162 Cost: $25,757 |
$16,274 | 378,841 | $6,888 | 662 | - | - | - | - |
$16,274 378,841 kWh |
$6,888 662 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $18,037 Cost: $46,350 |
$7,878 | 183,217 | $5,209 | 500 | - | - | $4,950 | - |
$7,878 183,217 kWh |
$5,209 500 kW-months/year |
- - Tgal |
$4,950 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $91,773 Cost: $9,040 |
- | - | - | - | $91,773 | 13,028 | - | - |
- - kWh |
- - kW-months/year |
$91,773 13,028 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $5,985 Cost: $29,286 |
$2,373 | 55,195 | $3,612 | 347 | - | - | - | - |
$2,373 55,195 kWh |
$3,612 347 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $402,938 Cost: $1,820,000 |
$263,527 | 6,128,535 | $139,411 | 13,392 | - | - | - | - |
$263,527 6,128,535 kWh |
$139,411 13,392 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $31,613 Cost: $98,280 |
$22,213 | 516,584 | $9,400 | 903 | - | - | - | - |
$22,213 516,584 kWh |
$9,400 903 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7273 INSTALL DESICCANT HUMIDITY CONTROL SYSTEM |
Savings: $76,144 Cost: $423,000 |
$47,756 | 1,110,595 | $28,388 | 2,727 | - | - | - | - |
$47,756 1,110,595 kWh |
$28,388 2,727 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $110,196 Cost: $55,220 |
$110,196 | 2,562,689 | - | - | - | - | - | - |
$110,196 2,562,689 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $759,848 Cost: $2,506,933 |
$470,217 | 10,935,656 | $192,908 | 18,531 | $91,773 | 13,028 | $4,950 | - | $470,217 10,935,656 kWh |
$192,908 18,531 kW-months/year |
$91,773 13,028 Tgal |
$4,950 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $170,570 Cost: $208,713 |
$48,738 | 1,133,837 | $25,109 | 2,412 | $91,773 | 13,028 | $4,950 | - | $48,738 1,133,837 kWh |
$25,109 2,412 kW-months/year |
$91,773 13,028 Tgal |
$4,950 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Water Disposal | One-time Revenue or Avoided Cost |