IAC logo
IAC Assessment: MZ1015
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MZ1015
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Missouri-Columbia
Assessment Year 2025
Principal Product Hotel
NAICS 721110 - Hotels (except Casino Hotels) and Motels
SIC 7011 - Hotels And Motels
Sales <$500,000
# of Employees 30
Plant Area (Sq.Ft.) 153,000
Annual Production 1 Pieces
Production Hrs. Annual 8,760
Location (State) MO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $125,360 1,583,200 kWh $0.08
Electricity Demand $59,005 3,270 kW-months/year $18.04
Natural Gas $55,449 5,127 MMBtu $10.82
TOTAL ENERGY COSTS $266,551
RECOMMENDED SAVINGS* $33,813 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$2,677
Cost:
$4,600
$2,677 33,805 - - - - - - $2,677
33,805
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
02: 2.9112 USE SOLAR HEAT TO HEAT WATER Savings:
$3,319
Cost:
$23,760
- - - - $3,319 307 - - -
-
kWh
-
-
kW-months/year
$3,319
307
MMBtu
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$517
Cost:
$496
$294 3,726 $90 5 - - $133 - $294
3,726
kWh
$90
5
kW-months/year
-
-
MMBtu
$133
-
$
04: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT Savings:
$14,776
Cost:
$6,332
$(-1,195) (-15,120) $(-379) (-21) $16,350 1,512 - - $(-1,195)
(-15,120)
kWh
$(-379)
(-21)
kW-months/year
$16,350
1,512
MMBtu
-
-
$
05: 2.6121 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED Savings:
$789
Cost:
-
- - - - $789 73 - - -
-
kWh
-
-
kW-months/year
$789
73
MMBtu
-
-
$
06: 2.2625 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE Savings:
$5,010
Cost:
$8,640
$5,010 63,418 - - - - - - $5,010
63,418
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
07: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD Savings:
$3,409
Cost:
$3,750
$1,245 15,768 $2,164 120 - - - - $1,245
15,768
kWh
$2,164
120
kW-months/year
-
-
MMBtu
-
-
$
08: 2.7314 REDUCE VENTILATION AIR Savings:
$3,316
Cost:
$5,000
$3,316 41,975 - - - - - - $3,316
41,975
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$33,813
Cost:
$52,578
$11,347 143,572 $1,875 104 $20,458 1,892 $133 - $11,347
143,572
kWh
$1,875
104
kW-months/year
$20,458
1,892
MMBtu
$133
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas One-time Revenue or Avoided Cost