IAC logo
IAC Assessment: NC0170
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: NC0170
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center North Carolina State
Assessment Year 1999
Principal Product Fork lifts
NAICS n/a
SIC 3537 - Industrial Trucks And Tractors
Sales $50,000,000-$100,000,000
# of Employees 325
Plant Area (Sq.Ft.) 143,000
Annual Production 10,000 Pieces
Production Hrs. Annual 6,000
Location (State) NC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $255,283 6,809,496 kWh $0.04
Electricity Demand $66,299 16,478 kW-months/year $4.02
Natural Gas $58,313 10,867 MMBtu $5.37
TOTAL ENERGY COSTS $417,287
RECOMMENDED SAVINGS* $42,101 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $4,977
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Water Disposal Other Liquid (haz) Water Consumption Electricity Usage Electricity Demand Natural Gas Water Disposal Other Liquid (haz) Water Consumption
$ kWh $ kW-months/year $ MMBtu $ Tgal $ gal $ Tgal
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,515
Cost:
-
$1,180 31,360 $1,335 70 - - - - - - - - $1,180
31,360
kWh
$1,335
70
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
gal
-
-
Tgal
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$1,345
Cost:
$500
$265 7,034 $1,080 57 - - - - - - - - $265
7,034
kWh
$1,080
57
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
gal
-
-
Tgal
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$2,462
Cost:
$2,000
- - - - $2,462 589 - - - - - - -
-
kWh
-
-
kW-months/year
$2,462
589
MMBtu
-
-
Tgal
-
-
gal
-
-
Tgal
04: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) Savings:
$2,763
Cost:
$200
- - - - - - $2,763 - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$2,763
-
Tgal
-
-
gal
-
-
Tgal
05: 3.3125 USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS Savings:
$29,116
Cost:
$20,000
- - - - $(-4,514) (-1,080) - - $33,630 59,000 - - -
-
kWh
-
-
kW-months/year
$(-4,514)
(-1,080)
MMBtu
-
-
Tgal
$33,630
59,000
gal
-
-
Tgal
06: 3.4151 MINIMIZE WATER USAGE Savings:
$3,900
Cost:
$50
- - - - - - - - - - $3,900 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
gal
$3,900
-
Tgal
TOTAL RECOMMENDED Savings:
$42,101
Cost:
$22,750
$1,445 38,394 $2,415 127 $(-2,052) (-491) $2,763 - $33,630 59,000 $3,900 - $1,445
38,394
kWh
$2,415
127
kW-months/year
$(-2,052)
(-491)
MMBtu
$2,763
-
Tgal
$33,630
59,000
gal
$3,900
-
Tgal
TOTAL IMPLEMENTED Savings:
$4,977
Cost:
$2,000
$1,180 31,360 $1,335 70 $2,462 589 - - - - - - $1,180
31,360
kWh
$1,335
70
kW-months/year
$2,462
589
MMBtu
-
-
Tgal
-
-
gal
-
-
Tgal
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ Tgal $ gal $ Tgal
Electricity Usage Electricity Demand Natural Gas Water Disposal Other Liquid (haz) Water Consumption Electricity Usage Electricity Demand Natural Gas Water Disposal Other Liquid (haz) Water Consumption