Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 1999 |
Principal Product | Office partition paneling fabric |
NAICS | n/a |
SIC | 2399 - Fabricated Textile Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 98,000 |
Annual Production | 1,500 Thousand Feet |
Production Hrs. Annual | 6,000 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $161,814 | 5,368,699 | kWh | $0.03 |
Electricity Demand | $90,904 | 10,790 | kW-months/year | $8.42 |
Electricity Fees | $7,856 | - | $ | - |
Natural Gas | $427,633 | 85,272 | MMBtu | $5.01 |
TOTAL ENERGY COSTS | $688,420 | |||
RECOMMENDED SAVINGS* | $276,922 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $43,536 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Water Consumption | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Water Consumption | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1133 ADJUST BURNERS FOR EFFICIENT OPERATION |
Savings: $1,107 Cost: $800 |
- | - | - | - | $607 | 121 | - | - | - | - | $500 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$607 121 MMBtu |
- - lb |
- - $ |
$500 - $ |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1133 ADJUST BURNERS FOR EFFICIENT OPERATION |
Savings: $35,782 Cost: $800 |
- | - | - | - | $35,782 | 7,135 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$35,782 7,135 MMBtu |
- - lb |
- - $ |
- - $ |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $4,918 Cost: $4,000 |
- | - | - | - | $4,918 | 982 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$4,918 982 MMBtu |
- - lb |
- - $ |
- - $ |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $877 Cost: $300 |
- | - | - | - | $877 | 175 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$877 175 MMBtu |
- - lb |
- - $ |
- - $ |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $852 Cost: $10 |
$548 | 18,171 | $304 | 36 | - | - | - | - | - | - | - | - | - | - | - | - |
$548 18,171 kWh |
$304 36 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $213 Cost: $400 |
- | - | - | - | - | - | $213 | 7,500 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$213 7,500 lb |
- - $ |
- - $ |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS |
Savings: $90,000 Cost: $7,500 |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | $90,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - Tgal |
$90,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.125 |
Savings: $143,173 Cost: $137,600 |
- | - | - | - | $48,333 | 9,647 | - | - | $57,240 | - | - | - | $37,600 | - | - | - |
- - kWh |
- - kW-months/year |
$48,333 9,647 MMBtu |
- - lb |
$57,240 - $ |
- - $ |
$37,600 - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $276,922 Cost: $151,410 |
$548 | 18,171 | $304 | 36 | $90,517 | 18,060 | $213 | 7,500 | $57,240 | - | $500 | - | $37,600 | - | $90,000 | - | $548 18,171 kWh |
$304 36 kW-months/year |
$90,517 18,060 MMBtu |
$213 7,500 lb |
$57,240 - $ |
$500 - $ |
$37,600 - Tgal |
$90,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $43,536 Cost: $5,910 |
$548 | 18,171 | $304 | 36 | $42,184 | 8,413 | - | - | - | - | $500 | - | - | - | - | - | $548 18,171 kWh |
$304 36 kW-months/year |
$42,184 8,413 MMBtu |
- - lb |
- - $ |
$500 - $ |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Water Consumption | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Water Consumption | Primary Product |