Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2000 |
Principal Product | PVC pellets |
NAICS | n/a |
SIC | 2821 - Plastics Materials And Resins |
Sales | $10,000,000-$50,000,000 |
# of Employees | 90 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 30,000,000 Pounds |
Production Hrs. Annual | 6,000 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $290,263 | 7,081,770 | kWh | $0.04 |
Electricity Demand | $106,114 | 22,107 | kW-months/year | $4.80 |
Electricity Fees | $7,779 | - | $ | - |
Natural Gas | $49,713 | 8,788 | MMBtu | $5.66 |
TOTAL ENERGY COSTS | $453,869 | |||
RECOMMENDED SAVINGS* | $60,699 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,081 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Consumption | One-time Revenue or Avoided Cost | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Water Consumption | One-time Revenue or Avoided Cost | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1133 ADJUST BURNERS FOR EFFICIENT OPERATION |
Savings: $1,081 Cost: $800 |
- | - | - | - | $1,081 | 191 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,081 191 MMBtu |
- - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,257 Cost: $180 |
$1,019 | 24,912 | $238 | 50 | - | - | - | - | - | - | - | - |
$1,019 24,912 kWh |
$238 50 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $1,275 Cost: $2,668 |
$1,099 | 26,671 | $176 | 37 | - | - | - | - | - | - | - | - |
$1,099 26,671 kWh |
$176 37 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,822 Cost: $100 |
$1,476 | 36,049 | $346 | 72 | - | - | - | - | - | - | - | - |
$1,476 36,049 kWh |
$346 72 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $5,045 Cost: $600 |
$4,118 | 100,528 | $927 | 193 | - | - | - | - | - | - | - | - |
$4,118 100,528 kWh |
$927 193 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2625 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE |
Savings: $4,905 Cost: $15,000 |
$4,559 | 111,372 | $346 | 72 | - | - | - | - | - | - | - | - |
$4,559 111,372 kWh |
$346 72 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.515 INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE |
Savings: $35,750 Cost: - |
- | - | - | - | - | - | - | - | $35,750 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$35,750 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.424 IMPROVE SPACE COMFORT CONDITIONING |
Savings: $9,564 Cost: $17,000 |
- | - | - | - | - | - | $(-2,500) | - | - | - | $12,064 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$(-2,500) - Tgal |
- - $ |
$12,064 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $60,699 Cost: $36,348 |
$12,271 | 299,532 | $2,033 | 424 | $1,081 | 191 | $(-2,500) | - | $35,750 | - | $12,064 | - | $12,271 299,532 kWh |
$2,033 424 kW-months/year |
$1,081 191 MMBtu |
$(-2,500) - Tgal |
$35,750 - $ |
$12,064 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,081 Cost: $800 |
- | - | - | - | $1,081 | 191 | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
$1,081 191 MMBtu |
- - Tgal |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Consumption | One-time Revenue or Avoided Cost | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Water Consumption | One-time Revenue or Avoided Cost | Increase in Production |