Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2002 |
Principal Product | Corrugated board and displays |
NAICS | n/a |
SIC | 2653 - Corrugated And Solid Fiber Boxes |
Sales | $50,000,000-$100,000,000 |
# of Employees | 220 |
Plant Area (Sq.Ft.) | 330,000 |
Annual Production | 1,000,000 Thousand Feet |
Production Hrs. Annual | 6,864 |
Location (State) | SC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $550,042 | 10,577,735 | kWh | $0.05 |
Electricity Demand | $156,868 | 31,374 | kW-months/year | $5.00 |
Electricity Fees | $300 | - | $ | - |
Natural Gas | $356,414 | 54,535 | MMBtu | $6.54 |
Fuel Oil #2 | $59,864 | 8,180 | MMBtu | $7.32 |
TOTAL ENERGY COSTS | $1,123,488 | |||
RECOMMENDED SAVINGS* | $241,302 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $72,125 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | One-time Revenue or Avoided Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | One-time Revenue or Avoided Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $17,277 Cost: $100 |
$14,793 | 284,475 | $2,484 | 497 | - | - | - | - | - | - | - | - |
$14,793 284,475 kWh |
$2,484 497 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.651 INSTALL BACK-UP EQUIPMENT |
Savings: $156,500 Cost: $1,000 |
- | - | - | - | - | - | - | - | $156,500 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$156,500 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $12,464 Cost: $550 |
- | - | - | - | $12,003 | 1,808 | $461 | 178,705 | - | - | - | - |
- - kWh |
- - kW-months/year |
$12,003 1,808 MMBtu |
$461 178,705 Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC |
Savings: $30,410 Cost: $1,000 |
- | - | - | - | - | - | - | - | - | - | $30,410 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
$30,410 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $23,267 Cost: $15,570 |
$19,907 | 382,822 | $3,360 | 672 | - | - | - | - | - | - | - | - |
$19,907 382,822 kWh |
$3,360 672 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,171 Cost: $2,434 |
$1,002 | 19,276 | $169 | 34 | - | - | - | - | - | - | - | - |
$1,002 19,276 kWh |
$169 34 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4115 RECOVER AND REUSE COOLING WATER |
Savings: $213 Cost: $500 |
- | - | - | - | - | - | $213 | 82,666 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$213 82,666 Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $241,302 Cost: $21,154 |
$35,702 | 686,573 | $6,013 | 1,203 | $12,003 | 1,808 | $674 | 261,371 | $156,500 | - | $30,410 | - | $35,702 686,573 kWh |
$6,013 1,203 kW-months/year |
$12,003 1,808 MMBtu |
$674 261,371 Tgal |
$156,500 - $ |
$30,410 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $72,125 Cost: $19,104 |
$35,702 | 686,573 | $6,013 | 1,203 | - | - | - | - | - | - | $30,410 | - | $35,702 686,573 kWh |
$6,013 1,203 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
$30,410 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | One-time Revenue or Avoided Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | One-time Revenue or Avoided Cost | Primary Product |