Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2002 |
Principal Product | Truck bodies and trailers |
NAICS | n/a |
SIC | 3715 - Truck Trailers |
Sales | $10,000,000-$50,000,000 |
# of Employees | 400 |
Plant Area (Sq.Ft.) | 200,000 |
Annual Production | 5,000 Pieces |
Production Hrs. Annual | 2,000 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $143,905 | 2,990,680 | kWh | $0.05 |
Electricity Demand | $52,979 | 12,859 | kW-months/year | $4.12 |
Electricity Fees | $2,056 | - | $ | - |
Natural Gas | $132,289 | 19,285 | MMBtu | $6.86 |
TOTAL ENERGY COSTS | $331,229 | |||
RECOMMENDED SAVINGS* | $26,669 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,046 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $2,879 Cost: $2,331 |
$1,902 | 39,527 | $977 | 237 | - | - |
$1,902 39,527 kWh |
$977 237 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4225 INSTALL COMMON HEADER ON COMPRESSORS |
Savings: $10,649 Cost: $17,871 |
$7,035 | 146,200 | $3,614 | 877 | - | - |
$7,035 146,200 kWh |
$3,614 877 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $7,280 Cost: $1,350 |
$7,280 | 151,289 | - | - | - | - |
$7,280 151,289 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,140 Cost: $2,000 |
- | - | - | - | $2,140 | 312 |
- - kWh |
- - kW-months/year |
$2,140 312 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $167 Cost: $150 |
$107 | 2,214 | $60 | 15 | - | - |
$107 2,214 kWh |
$60 15 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.9112 USE SOLAR HEAT TO HEAT WATER |
Savings: $3,554 Cost: $8,775 |
- | - | - | - | $3,554 | 415 |
- - kWh |
- - kW-months/year |
$3,554 415 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $26,669 Cost: $32,477 |
$16,324 | 339,230 | $4,651 | 1,129 | $5,694 | 727 | $16,324 339,230 kWh |
$4,651 1,129 kW-months/year |
$5,694 727 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,046 Cost: $2,481 |
$2,009 | 41,741 | $1,037 | 252 | - | - | $2,009 41,741 kWh |
$1,037 252 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |