Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center North Carolina State
Assessment Year 2005
Principal Product Pantyhose
NAICS 315110 - Hosiery and Sock Mills
SIC 2251 - Women's Full-Length and Knee-Length Hosiery, Except Socks
Sales $10,000,000-$50,000,000
# of Employees 130
Plant Area (Sq.Ft.) 150,000
Annual Production 24,000,000 Pieces
Production Hrs. Annual 6,000
Location (State) NC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $348,951 8,231,908 kWh $0.04
Electricity Demand $46,123 20,644 kW-months/year $2.23
Electricity Fees $106,905 - $ -
Fuel Oil #2 $151,887 12,657 MMBtu $12.00
TOTAL ENERGY COSTS $653,866
RECOMMENDED SAVINGS* $87,774 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $54,603
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Fuel Oil #2 Water Consumption Electricity Usage Electricity Demand Fuel Oil #2 Water Consumption
$ kWh $ kW-months/year $ MMBtu $ Tgal
01: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$19,862
Cost:
$24,000
$20,862 492,038 - - - - $(-1,000) - $20,862
492,038
kWh
-
-
kW-months/year
-
-
MMBtu
$(-1,000)
-
Tgal
02: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$22,562
Cost:
$8,181
- - - - $22,562 1,880 - - -
-
kWh
-
-
kW-months/year
$22,562
1,880
MMBtu
-
-
Tgal
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$33,171
Cost:
$27,875
$2,655 62,640 - - $30,516 2,543 - - $2,655
62,640
kWh
-
-
kW-months/year
$30,516
2,543
MMBtu
-
-
Tgal
04: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$2,834
Cost:
-
$2,681 63,240 $153 126 - - - - $2,681
63,240
kWh
$153
126
kW-months/year
-
-
MMBtu
-
-
Tgal
05: 2.7211 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS Savings:
$3,450
Cost:
$500
$3,341 78,789 $109 90 - - - - $3,341
78,789
kWh
$109
90
kW-months/year
-
-
MMBtu
-
-
Tgal
06: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$2,916
Cost:
$5,500
$2,916 138,356 - - - - - - $2,916
138,356
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$799
Cost:
$85
$769 18,133 $30 25 - - - - $769
18,133
kWh
$30
25
kW-months/year
-
-
MMBtu
-
-
Tgal
08: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$2,180
Cost:
$3,964
$2,062 48,621 $118 97 - - - - $2,062
48,621
kWh
$118
97
kW-months/year
-
-
MMBtu
-
-
Tgal
TOTAL RECOMMENDED Savings:
$87,774
Cost:
$70,105
$35,286 901,817 $410 338 $53,078 4,423 $(-1,000) - $35,286
901,817
kWh
$410
338
kW-months/year
$53,078
4,423
MMBtu
$(-1,000)
-
Tgal
TOTAL IMPLEMENTED Savings:
$54,603
Cost:
$42,230
$32,631 839,177 $410 338 $22,562 1,880 $(-1,000) - $32,631
839,177
kWh
$410
338
kW-months/year
$22,562
1,880
MMBtu
$(-1,000)
-
Tgal
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ Tgal
Electricity Usage Electricity Demand Fuel Oil #2 Water Consumption Electricity Usage Electricity Demand Fuel Oil #2 Water Consumption