Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2018 |
Principal Product | Chemicals |
NAICS | 325199 - All Other Basic Organic Chemical Manufacturing |
SIC | 2899 - Chemical Preparations, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 45,000 |
Annual Production | 10,000,000 Pounds |
Production Hrs. Annual | 6,000 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $53,840 | 986,988 | kWh | $0.05 |
Electricity Demand | $16,051 | 2,067 | kW-months/year | $7.77 |
Natural Gas | $33,838 | 5,402 | MMBtu | $6.26 |
TOTAL ENERGY COSTS | $121,879 | |||
RECOMMENDED SAVINGS* | $256,014 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Water Disposal | Ancillary Material Cost | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2615 CLEAN CONDENSER TUBES |
Savings: $226,480 Cost: $50,000 |
- | - | - | - | - | - | $(-30,000) | - | $256,480 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$(-30,000) - $ |
$256,480 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $909 Cost: $750 |
$708 | 12,960 | $201 | 26 | - | - | - | - | - | - |
$708 12,960 kWh |
$201 26 kW-months/year |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4154 AVOID REWINDING MOTORS MORE THAN TWICE |
Savings: $2,752 Cost: $5,685 |
$2,143 | 39,257 | $609 | 78 | - | - | - | - | - | - |
$2,143 39,257 kWh |
$609 78 kW-months/year |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $12,341 Cost: $2,450 |
- | - | - | - | $12,461 | 1,030 | $(-120) | - | - | - |
- - kWh |
- - kW-months/year |
$12,461 1,030 Tgal |
$(-120) - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $10,360 Cost: - |
$8,063 | 147,676 | $2,297 | 295 | - | - | - | - | - | - |
$8,063 147,676 kWh |
$2,297 295 kW-months/year |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $3,172 Cost: $500 |
$3,172 | - | - | - | - | - | - | - | - | - |
$3,172 - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $256,014 Cost: $59,385 |
$14,086 | 199,893 | $3,107 | 399 | $12,461 | 1,030 | $(-30,120) | - | $256,480 | - | $14,086 199,893 kWh |
$3,107 399 kW-months/year |
$12,461 1,030 Tgal |
$(-30,120) - $ |
$256,480 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Water Disposal | Ancillary Material Cost | Increase in Production |