Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Notre Dame Univ. |
---|---|
Assessment Year | 1996 |
Principal Product | Gypsum Wallboard |
NAICS | n/a |
SIC | 3275 - Gypsum Products |
Sales | $100,000,000-$500,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 207,500 |
Annual Production | 230,000 Thousand Feet |
Production Hrs. Annual | 8,424 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $435,725 | 12,417,644 | kWh | $0.04 |
Electricity Demand | $206,547 | 20,942 | kW-months/year | $9.86 |
Electricity Fees | $3,807 | - | $ | - |
Natural Gas | $1,276,944 | 560,745 | MMBtu | $2.28 |
TOTAL ENERGY COSTS | $1,924,520 | |||
RECOMMENDED SAVINGS* | $22,051 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,677 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $182 Cost: $340 |
$125 | 2,052 | $57 | 6 | - | - | - | - | - | - |
$125 2,052 kWh |
$57 6 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $238 Cost: $400 |
$238 | 6,741 | - | - | - | - | - | - | - | - |
$238 6,741 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $140 Cost: $840 |
$140 | 4,103 | - | - | - | - | - | - | - | - |
$140 4,103 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $780 Cost: $600 |
$780 | 22,274 | - | - | - | - | - | - | - | - |
$780 22,274 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $297 Cost: $243 |
$202 | 5,862 | $95 | 10 | - | - | - | - | - | - |
$202 5,862 kWh |
$95 10 kW-months/year |
- - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2427 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS |
Savings: $16,775 Cost: $12,966 |
- | - | - | - | - | - | $16,775 | 7,358 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$16,775 7,358 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $2,142 Cost: - |
- | - | - | - | $2,142 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,142 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.1161 ELIMINATE/REDUCE AN OPERATION |
Savings: $1,497 Cost: $190 |
- | - | - | - | - | - | - | - | $1,497 | 2,214 |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$1,497 2,214 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $22,051 Cost: $15,579 |
$1,485 | 41,032 | $152 | 16 | $2,142 | - | $16,775 | 7,358 | $1,497 | 2,214 | $1,485 41,032 kWh |
$152 16 kW-months/year |
$2,142 - $ |
$16,775 7,358 MMBtu |
$1,497 2,214 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,677 Cost: $643 |
$440 | 12,603 | $95 | 10 | $2,142 | - | - | - | - | - | $440 12,603 kWh |
$95 10 kW-months/year |
$2,142 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) |