Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Notre Dame Univ. |
---|---|
Assessment Year | 1996 |
Principal Product | Air Fresheners units |
NAICS | n/a |
SIC | 3433 - Heating Equipment, Except Electric |
Sales | $1,000,000-$5,000,000 |
# of Employees | 146 |
Plant Area (Sq.Ft.) | 36,000 |
Annual Production | 49,000,000 Pieces |
Production Hrs. Annual | 7,488 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $86,317 | 1,780,481 | kWh | $0.05 |
Electricity Demand | $19,738 | 3,743 | kW-months/year | $5.27 |
Natural Gas | $2,582 | 585 | MMBtu | $4.41 |
TOTAL ENERGY COSTS | $908,637 | |||
RECOMMENDED SAVINGS* | $56,001 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $140 Cost: $360 |
$112 | 2,638 | $28 | 7 | - | - | - | - |
$112 2,638 kWh |
$28 7 kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $37 Cost: $160 |
$31 | 586 | $6 | 1 | - | - | - | - |
$31 586 kWh |
$6 1 kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $2,761 Cost: $3,563 |
- | - | - | - | $2,761 | - | - | - |
- - kWh |
- - kW-months/year |
$2,761 - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $2,453 Cost: $1,000 |
$1,959 | 60,375 | $494 | 125 | - | - | - | - |
$1,959 60,375 kWh |
$494 125 kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $3,165 Cost: $1,000 |
$2,625 | 50,996 | $540 | 70 | - | - | - | - |
$2,625 50,996 kWh |
$540 70 kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $2,950 Cost: $800 |
- | - | - | - | $2,950 | - | - | - |
- - kWh |
- - kW-months/year |
$2,950 - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,524 Cost: $370 |
$1,215 | 36,049 | $309 | 78 | - | - | - | - |
$1,215 36,049 kWh |
$309 78 kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $232 Cost: $279 |
$172 | 2,638 | $60 | 8 | - | - | - | - |
$172 2,638 kWh |
$60 8 kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $52 Cost: $504 |
$52 | 1,172 | - | - | - | - | - | - |
$52 1,172 kWh |
- - kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $62 Cost: $504 |
$62 | 879 | - | - | - | - | - | - |
$62 879 kWh |
- - kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $457 Cost: $1,000 |
$457 | 11,137 | - | - | - | - | - | - |
$457 11,137 kWh |
- - kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,219 Cost: $1,000 |
$1,219 | 19,637 | - | - | - | - | - | - |
$1,219 19,637 kWh |
- - kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $257 Cost: $100 |
$257 | 6,448 | - | - | - | - | - | - |
$257 6,448 kWh |
- - kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $372 Cost: $100 |
$372 | 5,862 | - | - | - | - | - | - |
$372 5,862 kWh |
- - kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS |
Savings: $40,320 Cost: $340 |
- | - | - | - | - | - | $40,320 | 19,200 |
- - kWh |
- - kW-months/year |
- - $ |
$40,320 19,200 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $56,001 Cost: $11,080 |
$8,533 | 198,417 | $1,437 | 289 | $5,711 | - | $40,320 | 19,200 | $8,533 198,417 kWh |
$1,437 289 kW-months/year |
$5,711 - $ |
$40,320 19,200 lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - lb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) |