Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Notre Dame Univ. |
---|---|
Assessment Year | 1997 |
Principal Product | Steel bases and buildings |
NAICS | n/a |
SIC | 3441 - Fabricated Structural Metal |
Sales | $10,000,000-$50,000,000 |
# of Employees | 160 |
Plant Area (Sq.Ft.) | 101,000 |
Annual Production | 8,500 Tons |
Production Hrs. Annual | 5,406 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $112,347 | 1,922,040 | kWh | $0.06 |
Electricity Demand | $44,513 | 5,331 | kW-months/year | $8.35 |
Natural Gas | $46,830 | 9,695 | MMBtu | $4.83 |
TOTAL ENERGY COSTS | $203,690 | |||
RECOMMENDED SAVINGS* | $8,497 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $7,347 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Gaseous Waste | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Gaseous Waste | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $5,285 Cost: $2,390 |
$3,949 | 67,409 | $1,336 | 160 | - | - | - | - | - | - |
$3,949 67,409 kWh |
$1,336 160 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $698 Cost: $600 |
$421 | 12,016 | $277 | 33 | - | - | - | - | - | - |
$421 12,016 kWh |
$277 33 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $580 Cost: $100 |
$580 | 9,965 | - | - | - | - | - | - | - | - |
$580 9,965 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.7313 ELIMINATE OXYGEN LOSS |
Savings: $479 Cost: $20 |
- | - | - | - | - | - | $479 | 36 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$479 36 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $452 Cost: $400 |
$273 | 7,620 | $179 | 21 | - | - | - | - | - | - |
$273 7,620 kWh |
$179 21 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7495 INSTALL REPLACEMENT DOORS |
Savings: $355 Cost: $1,050 |
- | - | - | - | $355 | 64 | - | - | - | - |
- - kWh |
- - kW-months/year |
$355 64 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $325 Cost: - |
- | - | - | - | - | - | - | - | $325 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$325 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS |
Savings: $303 Cost: $335 |
- | - | - | - | $303 | 55 | - | - | - | - |
- - kWh |
- - kW-months/year |
$303 55 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $20 Cost: - |
$12 | 293 | $8 | 1 | - | - | - | - | - | - |
$12 293 kWh |
$8 1 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $8,497 Cost: $4,895 |
$5,235 | 97,303 | $1,800 | 215 | $658 | 119 | $479 | 36 | $325 | - | $5,235 97,303 kWh |
$1,800 215 kW-months/year |
$658 119 MMBtu |
$479 36 lb |
$325 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $7,347 Cost: $3,895 |
$4,541 | 77,667 | $1,344 | 161 | $658 | 119 | $479 | 36 | $325 | - | $4,541 77,667 kWh |
$1,344 161 kW-months/year |
$658 119 MMBtu |
$479 36 lb |
$325 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Gaseous Waste | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Gaseous Waste | Administrative Changes |