Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Notre Dame Univ. |
---|---|
Assessment Year | 1999 |
Principal Product | Hang Tabs |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 77 |
Plant Area (Sq.Ft.) | 90,000 |
Annual Production | 800,000,000 Pieces |
Production Hrs. Annual | 2,970 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $40,171 | 1,098,476 | kWh | $0.04 |
Electricity Demand | $72,156 | 6,560 | kW-months/year | $11.00 |
Natural Gas | $7,816 | 1,716 | MMBtu | $4.55 |
TOTAL ENERGY COSTS | $120,143 | |||
RECOMMENDED SAVINGS* | $6,385 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,637 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Wood | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Wood | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $131 Cost: - |
$58 | 1,758 | $73 | 7 | - | - | - | - | - | - | - | - |
$58 1,758 kWh |
$73 7 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $695 Cost: $1,893 |
$297 | 8,499 | $398 | 36 | - | - | - | - | - | - | - | - |
$297 8,499 kWh |
$398 36 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $303 Cost: $600 |
$133 | 3,810 | $170 | 15 | - | - | - | - | - | - | - | - |
$133 3,810 kWh |
$170 15 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $737 Cost: $255 |
$497 | 8,206 | $240 | 22 | - | - | - | - | - | - | - | - |
$497 8,206 kWh |
$240 22 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $320 Cost: $80 |
$274 | 3,224 | $46 | 4 | - | - | - | - | - | - | - | - |
$274 3,224 kWh |
$46 4 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $451 Cost: $455 |
$155 | 4,396 | $66 | 6 | - | - | - | - | $230 | - | - | - |
$155 4,396 kWh |
$66 6 kW-months/year |
- - MMBtu |
- - MMBtu |
$230 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $100 Cost: $153 |
$100 | 2,931 | - | - | - | - | - | - | - | - | - | - |
$100 2,931 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $1,251 Cost: $1,600 |
$312 | 8,792 | $1,188 | 108 | $(-249) | (-55) | - | - | - | - | - | - |
$312 8,792 kWh |
$1,188 108 kW-months/year |
$(-249) (-55) MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.222 PURCHASE RE-CONDITIONED MATERIAL INSTEAD OF NEW |
Savings: $969 Cost: $1,376 |
$249 | 3,810 | $172 | 12 | - | - | - | - | - | - | $548 | - |
$249 3,810 kWh |
$172 12 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
$548 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $1,428 Cost: $125 |
- | - | - | - | - | - | $1,428 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,428 - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $6,385 Cost: $6,537 |
$2,075 | 45,426 | $2,353 | 210 | $(-249) | (-55) | $1,428 | - | $230 | - | $548 | - | $2,075 45,426 kWh |
$2,353 210 kW-months/year |
$(-249) (-55) MMBtu |
$1,428 - MMBtu |
$230 - $ |
$548 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,637 Cost: $3,283 |
$1,414 | 29,893 | $993 | 90 | - | - | - | - | $230 | - | - | - | $1,414 29,893 kWh |
$993 90 kW-months/year |
- - MMBtu |
- - MMBtu |
$230 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Wood | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Wood | Ancillary Material Cost | One-time Revenue or Avoided Cost |