IAC logo
IAC Assessment: ND0322
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: ND0322
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Notre Dame Univ.
Assessment Year 1999
Principal Product Milled wheat
NAICS n/a
SIC 2041 - Flour And Other Grain Mill Products
Sales $10,000,000-$50,000,000
# of Employees 32
Plant Area (Sq.Ft.) 20,022
Annual Production 73,000,000 Pounds
Production Hrs. Annual 8,736
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $178,040 5,290,446 kWh $0.03
Electricity Demand $116,345 12,049 kW-months/year $9.66
Electricity Fees $12,301 - $ -
Natural Gas $24,732 6,768 MMBtu $3.65
TOTAL ENERGY COSTS $331,418
RECOMMENDED SAVINGS* $14,903 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $161
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Other Liquid (haz) Primary Product Electricity Usage Electricity Demand Natural Gas Other Liquid (haz) Primary Product
$ kWh $ kW-months/year $ MMBtu $ gal $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$639
Cost:
$1,458
$458 13,482 $181 19 - - - - - - $458
13,482
kWh
$181
19
kW-months/year
-
-
MMBtu
-
-
gal
-
-
$
02: 2.2211 USE OPTIMUM TEMPERATURE Savings:
$161
Cost:
-
$42 1,172 $119 12 - - - - - - $42
1,172
kWh
$119
12
kW-months/year
-
-
MMBtu
-
-
gal
-
-
$
03: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$1,357
Cost:
$1,250
$584 17,292 $1,043 108 $(-270) (-74) - - - - $584
17,292
kWh
$1,043
108
kW-months/year
$(-270)
(-74)
MMBtu
-
-
gal
-
-
$
04: 4.222 PURCHASE RE-CONDITIONED MATERIAL INSTEAD OF NEW Savings:
$2,056
Cost:
$38,197
$1,449 43,083 $607 59 - - - - - - $1,449
43,083
kWh
$607
59
kW-months/year
-
-
MMBtu
-
-
gal
-
-
$
05: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES Savings:
$10,625
Cost:
$4,000
- - - - - - - - $10,625 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
gal
$10,625
-
$
06: 3.8211 CONVERT TO AQUEOUS CLEANING SYSTEM Savings:
$65
Cost:
$20
- - - - - - $65 8 - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$65
8
gal
-
-
$
TOTAL RECOMMENDED Savings:
$14,903
Cost:
$44,925
$2,533 75,029 $1,950 198 $(-270) (-74) $65 8 $10,625 - $2,533
75,029
kWh
$1,950
198
kW-months/year
$(-270)
(-74)
MMBtu
$65
8
gal
$10,625
-
$
TOTAL IMPLEMENTED Savings:
$161
Cost:
-
$42 1,172 $119 12 - - - - - - $42
1,172
kWh
$119
12
kW-months/year
-
-
MMBtu
-
-
gal
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ gal $ $
Electricity Usage Electricity Demand Natural Gas Other Liquid (haz) Primary Product Electricity Usage Electricity Demand Natural Gas Other Liquid (haz) Primary Product