Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Notre Dame Univ. |
---|---|
Assessment Year | 1999 |
Principal Product | Dry Pet Food |
NAICS | n/a |
SIC | 2047 - Dog And Cat Food |
Sales | $100,000,000-$500,000,000 |
# of Employees | 245 |
Plant Area (Sq.Ft.) | 3,000,000 |
Annual Production | 990,500,000 Pounds |
Production Hrs. Annual | 6,240 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,181,080 | 31,195,487 | kWh | $0.04 |
Electricity Demand | $593,734 | 67,592 | kW-months/year | $8.78 |
TOTAL ENERGY COSTS | $1,774,814 | |||
RECOMMENDED SAVINGS* | $73,172 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $19,559 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | One-time Revenue or Avoided Cost | Primary Product | Electricity Usage | Electricity Demand | Personnel Changes | One-time Revenue or Avoided Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $802 Cost: $1,525 |
$423 | 22,567 | $379 | 43 | - | - | - | - | - | - |
$423 22,567 kWh |
$379 43 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,051 Cost: $250 |
$554 | 29,601 | $497 | 57 | - | - | - | - | - | - |
$554 29,601 kWh |
$497 57 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $7,258 Cost: $30,000 |
$4,427 | 235,346 | $2,831 | 322 | - | - | - | - | - | - |
$4,427 235,346 kWh |
$2,831 322 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $52,604 Cost: $41,503 |
$1,240 | 65,944 | $1,113 | 126 | - | - | $50,251 | - | - | - |
$1,240 65,944 kWh |
$1,113 126 kW-months/year |
- - $ |
$50,251 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $459 Cost: $1,800 |
$476 | 25,205 | $463 | 53 | $(-480) | - | - | - | - | - |
$476 25,205 kWh |
$463 53 kW-months/year |
$(-480) - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $(-252) Cost: - |
- | - | - | - | $(-252) | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$(-252) - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.1192 REDUCE SCRAP PRODUCTION |
Savings: $11,250 Cost: $7,200 |
- | - | - | - | $3,750 | - | - | - | $7,500 | - |
- - kWh |
- - kW-months/year |
$3,750 - $ |
- - $ |
$7,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $73,172 Cost: $82,278 |
$7,120 | 378,663 | $5,283 | 601 | $3,018 | - | $50,251 | - | $7,500 | - | $7,120 378,663 kWh |
$5,283 601 kW-months/year |
$3,018 - $ |
$50,251 - $ |
$7,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $19,559 Cost: $37,450 |
$4,981 | 264,947 | $3,328 | 379 | $3,750 | - | - | - | $7,500 | - | $4,981 264,947 kWh |
$3,328 379 kW-months/year |
$3,750 - $ |
- - $ |
$7,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | One-time Revenue or Avoided Cost | Primary Product | Electricity Usage | Electricity Demand | Personnel Changes | One-time Revenue or Avoided Cost | Primary Product |