Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Notre Dame Univ. |
---|---|
Assessment Year | 1999 |
Principal Product | Fire Fighting Nozzles |
NAICS | n/a |
SIC | 3569 - General Industrial Machinery, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 80,000 |
Annual Production | 2,500 Pieces |
Production Hrs. Annual | 4,160 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $83,953 | 1,331,770 | kWh | $0.06 |
Electricity Demand | $31,363 | 3,828 | kW-months/year | $8.19 |
Natural Gas | $4,061 | 718 | MMBtu | $5.66 |
TOTAL ENERGY COSTS | $123,958 | |||
RECOMMENDED SAVINGS* | $48,868 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $40,768 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Personnel Changes | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Personnel Changes | Administrative Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.521 CLEAR AND RENT EXISTING SPACE |
Savings: $40,000 Cost: $18,000 |
- | - | - | - | - | - | - | - | - | - | $40,000 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - $ |
$40,000 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $720 Cost: $7,006 |
$621 | 5,862 | $99 | 12 | - | - | - | - | - | - | - | - | - | - |
$621 5,862 kWh |
$99 12 kW-months/year |
- - $ |
- - Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $2,442 Cost: $5,000 |
$2,442 | 44,549 | - | - | - | - | - | - | - | - | - | - | - | - |
$2,442 44,549 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,236 Cost: $1,500 |
$1,236 | 21,981 | - | - | - | - | - | - | - | - | - | - | - | - |
$1,236 21,981 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,296 Cost: $300 |
$898 | 16,413 | $398 | 43 | - | - | - | - | - | - | - | - | - | - |
$898 16,413 kWh |
$398 43 kW-months/year |
- - $ |
- - Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4151 MINIMIZE WATER USAGE |
Savings: $870 Cost: $1,400 |
- | - | - | - | - | - | $870 | 98,800 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$870 98,800 Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4151 MINIMIZE WATER USAGE |
Savings: $878 Cost: $2,300 |
- | - | - | - | - | - | $755 | 85,800 | $200 | - | - | - | $(-77) | - |
- - kWh |
- - kW-months/year |
- - $ |
$755 85,800 Tgal |
$200 - $ |
- - $ |
$(-77) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.811 DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS |
Savings: $658 Cost: $250 |
- | - | - | - | $658 | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$658 - $ |
- - Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $587 Cost: $100 |
$587 | 10,844 | - | - | - | - | - | - | - | - | - | - | - | - |
$587 10,844 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $181 Cost: $390 |
- | - | - | - | - | - | - | - | $181 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
$181 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $48,868 Cost: $36,246 |
$5,784 | 99,649 | $497 | 55 | $658 | - | $1,625 | 184,600 | $381 | - | $40,000 | - | $(-77) | - | $5,784 99,649 kWh |
$497 55 kW-months/year |
$658 - $ |
$1,625 184,600 Tgal |
$381 - $ |
$40,000 - $ |
$(-77) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $40,768 Cost: $18,490 |
$587 | 10,844 | - | - | - | - | - | - | $181 | - | $40,000 | - | - | - | $587 10,844 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
$181 - $ |
$40,000 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Personnel Changes | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Personnel Changes | Administrative Changes | Primary Raw Material |