IAC logo
IAC Assessment: ND0332
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: ND0332
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Notre Dame Univ.
Assessment Year 1999
Principal Product Vitreous china plumbing fixtures
NAICS n/a
SIC 3261 - Vitreous Plumbing Fixtures
Sales $10,000,000-$50,000,000
# of Employees 203
Plant Area (Sq.Ft.) 500,000
Annual Production 1,000,000 Pieces
Production Hrs. Annual 4,420
Location (State) IN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $140,795 8,621,044 kWh $0.02
Electricity Demand $183,079 16,541 kW-months/year $11.07
Natural Gas $649,748 187,783 MMBtu $3.46
TOTAL ENERGY COSTS $973,622
RECOMMENDED SAVINGS* $13,487 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $6,942
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$2,688
Cost:
$750
$979 56,565 $1,709 153 - - - - - - $979
56,565
kWh
$1,709
153
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,197
Cost:
$7,544
$1,112 64,185 $1,942 174 - - $(-20) - $163 - $1,112
64,185
kWh
$1,942
174
kW-months/year
-
-
MMBtu
$(-20)
-
$
$163
-
$
03: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$117
Cost:
$40
$27 1,465 $90 8 - - - - - - $27
1,465
kWh
$90
8
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$(-61)
Cost:
$1,560
$102 5,862 $90 8 - - $(-463) - $210 - $102
5,862
kWh
$90
8
kW-months/year
-
-
MMBtu
$(-463)
-
$
$210
-
$
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$2,668
Cost:
$500
$733 42,204 $1,935 174 - - - - - - $733
42,204
kWh
$1,935
174
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,580
Cost:
$480
$1,580 91,149 - - - - - - - - $1,580
91,149
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$2,577
Cost:
$1,200
- - - - $2,577 741 - - - - -
-
kWh
-
-
kW-months/year
$2,577
741
MMBtu
-
-
$
-
-
$
08: 4.6110 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE Savings:
$721
Cost:
$1,334
- - - - - - $721 - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$721
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$13,487
Cost:
$13,408
$4,533 261,430 $5,766 517 $2,577 741 $238 - $373 - $4,533
261,430
kWh
$5,766
517
kW-months/year
$2,577
741
MMBtu
$238
-
$
$373
-
$
TOTAL IMPLEMENTED Savings:
$6,942
Cost:
$2,220
$2,340 134,818 $2,025 182 $2,577 741 - - - - $2,340
134,818
kWh
$2,025
182
kW-months/year
$2,577
741
MMBtu
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost