Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Notre Dame Univ. |
---|---|
Assessment Year | 2000 |
Principal Product | Fiber Board |
NAICS | n/a |
SIC | 2631 - Paperboard Mills |
Sales | $10,000,000-$50,000,000 |
# of Employees | 75 |
Plant Area (Sq.Ft.) | 160,000 |
Annual Production | 5,000 Thousand Feet |
Production Hrs. Annual | 2,210 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $117,963 | 2,283,998 | kWh | $0.05 |
Electricity Demand | $19,511 | 6,155 | kW-months/year | $3.17 |
TOTAL ENERGY COSTS | $137,474 | |||
RECOMMENDED SAVINGS* | $6,459 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,882 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $386 Cost: - |
$386 | 7,620 | - | - | - | - | - | - | - | - | - | - | - | - |
$386 7,620 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $587 Cost: $590 |
$179 | 3,517 | $15 | 5 | - | - | $270 | - | - | - | $123 | - | - | - |
$179 3,517 kWh |
$15 5 kW-months/year |
- - $ |
$270 - $ |
- - $ |
$123 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $124 Cost: $350 |
$93 | 1,758 | $31 | 10 | - | - | - | - | - | - | - | - | - | - |
$93 1,758 kWh |
$31 10 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $862 Cost: $6,560 |
$649 | 12,603 | $213 | 67 | - | - | - | - | - | - | - | - | - | - |
$649 12,603 kWh |
$213 67 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $913 Cost: - |
$442 | 8,499 | $221 | 70 | - | - | - | - | $250 | - | - | - | - | - |
$442 8,499 kWh |
$221 70 kW-months/year |
- - $ |
- - $ |
$250 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.425 ELIMINATE/REDUCE REDUNDANT INSPECTIONS |
Savings: $134 Cost: - |
- | - | - | - | - | - | $134 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$134 - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3511 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS |
Savings: $2,211 Cost: $200 |
- | - | - | - | $(-3,585) | - | - | - | - | - | - | - | $5,796 | - |
- - kWh |
- - kW-months/year |
$(-3,585) - $ |
- - $ |
- - $ |
- - $ |
$5,796 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $1,242 Cost: $250 |
- | - | - | - | $1,242 | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,242 - $ |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $6,459 Cost: $7,950 |
$1,749 | 33,997 | $480 | 152 | $(-2,343) | - | $404 | - | $250 | - | $123 | - | $5,796 | - | $1,749 33,997 kWh |
$480 152 kW-months/year |
$(-2,343) - $ |
$404 - $ |
$250 - $ |
$123 - $ |
$5,796 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,882 Cost: $7,150 |
$1,656 | 32,239 | $449 | 142 | - | - | $404 | - | $250 | - | $123 | - | - | - | $1,656 32,239 kWh |
$449 142 kW-months/year |
- - $ |
$404 - $ |
$250 - $ |
$123 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost |