IAC logo
IAC Assessment: ND0347
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: ND0347
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Notre Dame Univ.
Assessment Year 2000
Principal Product Automotive Seating
NAICS n/a
SIC 3714 - Motor Vehicle Parts And Accessories
Sales $10,000,000-$50,000,000
# of Employees 250
Plant Area (Sq.Ft.) 83,000
Annual Production 193,000 Pieces
Production Hrs. Annual 4,250
Location (State) IN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $33,528 2,035,170 kWh $0.02
Electricity Demand $54,119 5,290 kW-months/year $10.23
Electricity Fees $3,567 - $ -
Natural Gas $10,754 1,969 MMBtu $5.46
TOTAL ENERGY COSTS $101,968
RECOMMENDED SAVINGS* $17,043 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $14,483
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$125
Cost:
$100
$125 7,620 - - - - $125
7,620
kWh
-
-
kW-months/year
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,121
Cost:
$6,762
$663 40,152 $1,458 143 - - $663
40,152
kWh
$1,458
143
kW-months/year
-
-
MMBtu
03: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$13,997
Cost:
$11,000
$5,453 330,891 $15,506 1,516 $(-6,962) (-1,299) $5,453
330,891
kWh
$15,506
1,516
kW-months/year
$(-6,962)
(-1,299)
MMBtu
04: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE Savings:
$115
Cost:
-
$115 6,448 - - - - $115
6,448
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.4151 DEVELOP A REPAIR/REPLACE POLICY Savings:
$360
Cost:
$843
$131 7,913 $229 22 - - $131
7,913
kWh
$229
22
kW-months/year
-
-
MMBtu
06: 2.2211 USE OPTIMUM TEMPERATURE Savings:
$10
Cost:
$8
$10 586 - - - - $10
586
kWh
-
-
kW-months/year
-
-
MMBtu
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$236
Cost:
$900
$126 7,620 $110 11 - - $126
7,620
kWh
$110
11
kW-months/year
-
-
MMBtu
08: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$79
Cost:
$340
$110 4,982 $82 11 $(-113) (-21) $110
4,982
kWh
$82
11
kW-months/year
$(-113)
(-21)
MMBtu
TOTAL RECOMMENDED Savings:
$17,043
Cost:
$19,953
$6,733 406,212 $17,385 1,703 $(-7,075) (-1,320) $6,733
406,212
kWh
$17,385
1,703
kW-months/year
$(-7,075)
(-1,320)
MMBtu
TOTAL IMPLEMENTED Savings:
$14,483
Cost:
$12,008
$5,829 353,165 $15,616 1,527 $(-6,962) (-1,299) $5,829
353,165
kWh
$15,616
1,527
kW-months/year
$(-6,962)
(-1,299)
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas