Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
IAC Center | Notre Dame Univ. |
---|---|
Assessment Year | 2000 |
Principal Product | Tie Rods and Drag Links |
NAICS | n/a |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $50,000,000-$100,000,000 |
# of Employees | 390 |
Plant Area (Sq.Ft.) | 192,000 |
Annual Production | 2,188,000 Pieces |
Production Hrs. Annual | 7,344 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $406,128 | 12,651,231 | kWh | $0.03 |
Electricity Demand | $209,070 | 31,507 | kW-months/year | $6.64 |
Electricity Fees | $58,285 | - | $ | - |
Natural Gas | $146,525 | 43,188 | MMBtu | $3.39 |
TOTAL ENERGY COSTS | $820,008 | |||
RECOMMENDED SAVINGS* | $9,915 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $9,492 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,021 Cost: $8,040 |
$446 | 16,999 | $575 | 72 | - | - | - | - |
$446 16,999 kWh |
$575 72 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $7,260 Cost: $520 |
$7,260 | 226,260 | - | - | - | - | - | - |
$7,260 226,260 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $189 Cost: $380 |
$64 | 2,052 | $18 | 32 | - | - | $107 | - |
$64 2,052 kWh |
$18 32 kW-months/year |
- - $ |
$107 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $234 Cost: $300 |
$175 | 5,569 | $59 | 9 | - | - | - | - |
$175 5,569 kWh |
$59 9 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $1,211 Cost: - |
- | - | - | - | $1,211 | - | - | - |
- - kWh |
- - kW-months/year |
$1,211 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $9,915 Cost: $9,240 |
$7,945 | 250,880 | $652 | 113 | $1,211 | - | $107 | - | $7,945 250,880 kWh |
$652 113 kW-months/year |
$1,211 - $ |
$107 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $9,492 Cost: $8,560 |
$7,706 | 243,259 | $575 | 72 | $1,211 | - | - | - | $7,706 243,259 kWh |
$575 72 kW-months/year |
$1,211 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Ancillary Material Cost |