Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Notre Dame Univ. |
---|---|
Assessment Year | 2000 |
Principal Product | metal stampings |
NAICS | n/a |
SIC | 3499 - Fabricated Metal Products, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 370 |
Plant Area (Sq.Ft.) | 148,000 |
Annual Production | 36,500,000 Pieces |
Production Hrs. Annual | 7,878 |
Location (State) | IN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $167,090 | 7,369,285 | kWh | $0.02 |
Electricity Demand | $142,432 | 14,170 | kW-months/year | $10.05 |
Natural Gas | $92,106 | 23,982 | MMBtu | $3.84 |
TOTAL ENERGY COSTS | $401,628 | |||
RECOMMENDED SAVINGS* | $17,378 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,892 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $8,340 Cost: $22,377 |
$4,981 | 230,070 | $3,359 | 334 | - | - | - | - | - | - | - | - |
$4,981 230,070 kWh |
$3,359 334 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $3,206 Cost: - |
$1,808 | 79,719 | $1,220 | 121 | - | - | - | - | $178 | - | - | - |
$1,808 79,719 kWh |
$1,220 121 kW-months/year |
- - MMBtu |
- - $ |
$178 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $839 Cost: $600 |
$494 | 21,688 | $345 | 34 | - | - | - | - | - | - | - | - |
$494 21,688 kWh |
$345 34 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $271 Cost: $575 |
$52 | 2,052 | $31 | 3 | - | - | $123 | - | $65 | - | - | - |
$52 2,052 kWh |
$31 3 kW-months/year |
- - MMBtu |
$123 - $ |
$65 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,221 Cost: $1,000 |
$1,924 | 84,701 | $1,297 | 129 | - | - | - | - | - | - | - | - |
$1,924 84,701 kWh |
$1,297 129 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $75 Cost: $200 |
$75 | 3,224 | - | - | - | - | - | - | - | - | - | - |
$75 3,224 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $605 Cost: $400 |
$198 | 8,792 | $543 | 54 | $(-136) | (-35) | - | - | - | - | - | - |
$198 8,792 kWh |
$543 54 kW-months/year |
$(-136) (-35) MMBtu |
- - $ |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4151 MINIMIZE WATER USAGE |
Savings: $821 Cost: $2,875 |
- | - | - | - | - | - | $250 | - | $(-227) | - | $798 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$250 - $ |
$(-227) - $ |
$798 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $17,378 Cost: $28,027 |
$9,532 | 430,246 | $6,795 | 675 | $(-136) | (-35) | $373 | - | $16 | - | $798 | - | $9,532 430,246 kWh |
$6,795 675 kW-months/year |
$(-136) (-35) MMBtu |
$373 - $ |
$16 - $ |
$798 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,892 Cost: $23,152 |
$6,916 | 315,065 | $4,610 | 458 | - | - | $123 | - | $243 | - | - | - | $6,916 315,065 kWh |
$4,610 458 kW-months/year |
- - MMBtu |
$123 - $ |
$243 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||