Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nebraska–Lincoln |
---|---|
Assessment Year | 2018 |
Principal Product | Compressed Natural Gas Tanks for Large Vehicle Use |
NAICS | 336390 - Other Motor Vehicle Parts Manufacturing |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $50,000,000-$100,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 108,000 |
Annual Production | 30,000 Units |
Production Hrs. Annual | 7,200 |
Location (State) | NE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $151,368 | 5,792,800 | kWh | $0.03 |
Electricity Demand | $206,851 | 10,825 | kW-months/year | $19.11 |
Electricity Fees | $86,616 | - | $ | - |
Natural Gas | $90,719 | 13,663 | MMBtu | $6.64 |
TOTAL ENERGY COSTS | $581,970 | |||
RECOMMENDED SAVINGS* | $49,070 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $43,963 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Usage | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Water Usage | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $24,797 Cost: $32,620 |
$(-1,123) | (-43,200) | - | - | $12,960 | 4,320 | $12,960 | 4,320 | - | - |
$(-1,123) (-43,200) kWh |
- - kW-months/year |
$12,960 4,320 Tgal |
$12,960 4,320 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $18,840 Cost: $74,980 |
$11,091 | 426,585 | $10,709 | 560 | - | - | - | - | $(-2,960) | - |
$11,091 426,585 kWh |
$10,709 560 kW-months/year |
- - Tgal |
- - Tgal |
$(-2,960) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $4,500 Cost: $2,500 |
$2,264 | 87,000 | $2,236 | 117 | - | - | - | - | - | - |
$2,264 87,000 kWh |
$2,236 117 kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $607 Cost: $1,050 |
$607 | 23,339 | - | - | - | - | - | - | - | - |
$607 23,339 kWh |
- - kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $326 Cost: $1,000 |
$452 | 17,636 | - | - | - | - | - | - | $(-126) | - |
$452 17,636 kWh |
- - kW-months/year |
- - Tgal |
- - Tgal |
$(-126) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $49,070 Cost: $112,150 |
$13,291 | 511,360 | $12,945 | 677 | $12,960 | 4,320 | $12,960 | 4,320 | $(-3,086) | - | $13,291 511,360 kWh |
$12,945 677 kW-months/year |
$12,960 4,320 Tgal |
$12,960 4,320 Tgal |
$(-3,086) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $43,963 Cost: $108,600 |
$10,420 | 401,021 | $10,709 | 560 | $12,960 | 4,320 | $12,960 | 4,320 | $(-3,086) | - | $10,420 401,021 kWh |
$10,709 560 kW-months/year |
$12,960 4,320 Tgal |
$12,960 4,320 Tgal |
$(-3,086) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Usage | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Water Usage | Water Disposal | Personnel Changes |