Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nebraska–Lincoln |
---|---|
Assessment Year | 2019 |
Principal Product | Ethanol |
NAICS | 325193 - Ethyl Alcohol Manufacturing |
SIC | 2869 - Industrial Organic Chemicals, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 32 |
Plant Area (Sq.Ft.) | 215,150 |
Annual Production | 25,000 Thousand Gallons |
Production Hrs. Annual | 8,592 |
Location (State) | NE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $886,832 | 18,262,321 | kWh | $0.05 |
Electricity Demand | $366,292 | 30,199 | kW-months/year | $12.13 |
Electricity Fees | $2,404 | - | $ | - |
Natural Gas | $1,102,401 | 436,129 | MMBtu | $2.53 |
TOTAL ENERGY COSTS | $2,357,929 | |||
RECOMMENDED SAVINGS* | $1,120,223 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,114,998 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2211 USE OPTIMUM TEMPERATURE |
Savings: $1,023,132 Cost: $178,000 |
$(-17,699) | (-361,200) | $(-12,169) | (-1,003) | - | - | - | - | - | - | $1,053,000 | - |
$(-17,699) (-361,200) kWh |
$(-12,169) (-1,003) kW-months/year |
- - MMBtu |
- - $ |
- - $ |
$1,053,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1222 INSTALL TURBULATORS |
Savings: $66,132 Cost: $93,000 |
- | - | - | - | $66,132 | 26,160 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$66,132 26,160 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $13,344 Cost: $46,600 |
$13,344 | 272,362 | - | - | - | - | - | - | - | - | - | - |
$13,344 272,362 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $12,390 Cost: $24,394 |
$9,318 | 190,179 | $3,072 | 253 | - | - | - | - | - | - | - | - |
$9,318 190,179 kWh |
$3,072 253 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $5,225 Cost: $1,600 |
- | - | - | - | $6,197 | 2,449 | $(-472) | - | $(-500) | - | - | - |
- - kWh |
- - kW-months/year |
$6,197 2,449 MMBtu |
$(-472) - $ |
$(-500) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,120,223 Cost: $343,594 |
$4,963 | 101,341 | $(-9,097) | (-750) | $72,329 | 28,609 | $(-472) | - | $(-500) | - | $1,053,000 | - | $4,963 101,341 kWh |
$(-9,097) (-750) kW-months/year |
$72,329 28,609 MMBtu |
$(-472) - $ |
$(-500) - $ |
$1,053,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,114,998 Cost: $341,994 |
$4,963 | 101,341 | $(-9,097) | (-750) | $66,132 | 26,160 | - | - | - | - | $1,053,000 | - | $4,963 101,341 kWh |
$(-9,097) (-750) kW-months/year |
$66,132 26,160 MMBtu |
- - $ |
- - $ |
$1,053,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product |