Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nebraska–Lincoln |
---|---|
Assessment Year | 2021 |
Principal Product | Precision Aircraft Parts |
NAICS | 336413 - Other Aircraft Parts and Auxiliary Equipment Manufacturing |
SIC | 3728 - Aircraft Parts And Equipment, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 179 |
Plant Area (Sq.Ft.) | 140,000 |
Annual Production | 6,500,000 Units |
Production Hrs. Annual | 6,240 |
Location (State) | NE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $422,441 | 10,804,130 | kWh | $0.04 |
Electricity Demand | $310,782 | 14,368 | kW-months/year | $21.63 |
Natural Gas | $60,858 | 7,909 | MMBtu | $7.70 |
TOTAL ENERGY COSTS | $813,959 | |||
RECOMMENDED SAVINGS* | $319,632 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $7,879 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Water Disposal | Ancillary Material Cost | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $282,217 Cost: $1,200,000 |
$178,393 | 4,562,480 | $103,824 | 4,800 | - | - | - | - | - | - |
$178,393 4,562,480 kWh |
$103,824 4,800 kW-months/year |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $24,583 Cost: $30,000 |
$(-1,171) | (-29,952) | $(-1,246) | (-58) | - | - | - | - | $27,000 | - |
$(-1,171) (-29,952) kWh |
$(-1,246) (-58) kW-months/year |
- - Tgal |
- - $ |
$27,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,369 Cost: $6,060 |
$1,918 | 48,952 | $2,007 | 93 | - | - | - | - | - | - |
$1,918 48,952 kWh |
$2,007 93 kW-months/year |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,510 Cost: $2,500 |
$4,122 | 105,417 | - | - | - | - | $(-100) | - | - | - |
$4,122 105,417 kWh |
- - kW-months/year |
- - Tgal |
$(-100) - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4155 METER WASTE WATER |
Savings: $2,893 Cost: $1,106 |
- | - | - | - | $2,893 | 786 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,893 786 Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,164 Cost: $728 |
$1,164 | 29,768 | - | - | - | - | - | - | - | - |
$1,164 29,768 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $896 Cost: $997 |
$828 | 21,175 | - | - | - | - | - | - | - | - |
$828 21,175 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $319,632 Cost: $1,241,391 |
$185,254 | 4,737,840 | $104,585 | 4,835 | $2,893 | 786 | $(-100) | - | $27,000 | - | $185,254 4,737,840 kWh |
$104,585 4,835 kW-months/year |
$2,893 786 Tgal |
$(-100) - $ |
$27,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $7,879 Cost: $8,560 |
$6,040 | 154,369 | $2,007 | 93 | - | - | $(-100) | - | - | - | $6,040 154,369 kWh |
$2,007 93 kW-months/year |
- - Tgal |
$(-100) - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Water Disposal | Ancillary Material Cost | Increase in Production |