Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nebraska–Lincoln |
---|---|
Assessment Year | 2022 |
Principal Product | Salad Dressing |
NAICS | 311941 - Mayonnaise, Dressing, and Other Prepared Sauce Manufacturing |
SIC | 2035 - Pickles, Sauces, And Salad Dressings |
Sales | $1,000,000-$5,000,000 |
# of Employees | 13 |
Plant Area (Sq.Ft.) | 64,000 |
Annual Production | 2,250,000 Pounds |
Production Hrs. Annual | 2,000 |
Location (State) | NE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $63,767 | 1,441,067 | kWh | $0.04 |
Electricity Demand | $34,251 | 2,303 | kW-months/year | $14.88 |
Electricity Fees | $5,440 | - | $ | - |
LPG | $8,770 | 459 | MMBtu | $19.13 |
TOTAL ENERGY COSTS | $112,228 | |||
RECOMMENDED SAVINGS* | $584,460 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $332,298 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Personnel Changes | Primary Raw Material | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | LPG | Personnel Changes | Primary Raw Material | Ancillary Material Cost | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.2172 USE AUTOMATIC CLEANING EQUIPMENT |
Savings: $250,000 Cost: $215,120 |
- | - | - | - | - | - | - | - | - | - | - | - | $250,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
$250,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $250,000 Cost: $150,000 |
- | - | - | - | - | - | - | - | - | - | - | - | $250,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
$250,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.132 PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST |
Savings: $49,500 Cost: $95,000 |
- | - | - | - | - | - | - | - | $49,500 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$49,500 - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $16,645 Cost: $32,028 |
$32,108 | 338,000 | - | - | $(-15,463) | (-809) | - | - | - | - | - | - | - | - |
$32,108 338,000 kWh |
- - kW-months/year |
$(-15,463) (-809) MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $11,640 Cost: $13,920 |
$11,640 | 122,535 | - | - | - | - | - | - | - | - | - | - | - | - |
$11,640 122,535 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,513 Cost: $7,203 |
$1,607 | 36,520 | $2,906 | 195 | - | - | - | - | - | - | - | - | - | - |
$1,607 36,520 kWh |
$2,906 195 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7234 USE HEAT PUMP FOR SPACE CONDITIONING |
Savings: $1,731 Cost: $8,247 |
$1,731 | 18,225 | - | - | - | - | - | - | - | - | - | - | - | - |
$1,731 18,225 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $431 Cost: $500 |
$541 | 11,886 | - | - | - | - | $(-60) | - | - | - | $(-50) | - | - | - |
$541 11,886 kWh |
- - kW-months/year |
- - MMBtu |
$(-60) - $ |
- - $ |
$(-50) - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $584,460 Cost: $522,018 |
$47,627 | 527,166 | $2,906 | 195 | $(-15,463) | (-809) | $(-60) | - | $49,500 | - | $(-50) | - | $500,000 | - | $47,627 527,166 kWh |
$2,906 195 kW-months/year |
$(-15,463) (-809) MMBtu |
$(-60) - $ |
$49,500 - $ |
$(-50) - $ |
$500,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $332,298 Cost: $363,271 |
$45,355 | 497,055 | $2,906 | 195 | $(-15,463) | (-809) | - | - | $49,500 | - | - | - | $250,000 | - | $45,355 497,055 kWh |
$2,906 195 kW-months/year |
$(-15,463) (-809) MMBtu |
- - $ |
$49,500 - $ |
- - $ |
$250,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Personnel Changes | Primary Raw Material | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | LPG | Personnel Changes | Primary Raw Material | Ancillary Material Cost | Increase in Production |