Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Nebraska–Lincoln
Assessment Year 2023
Principal Product Snack Nuts
NAICS 311919 - Other Snack Food Manufacturing
SIC 2068 - Salted And Roasted Nuts And Seeds
Sales $10,000,000-$50,000,000
# of Employees 120
Plant Area (Sq.Ft.) 170,800
Annual Production 18,000,000 Units
Production Hrs. Annual 2,600
Location (State) NE
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $100,668 1,548,738 kWh $0.07
Electricity Demand $33,679 6,260 kW-months/year $5.38
Electricity Fees $6,583 - $ -
Natural Gas $71,903 8,726 MMBtu $8.24
TOTAL ENERGY COSTS $220,395
RECOMMENDED SAVINGS* $62,240 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Personnel Changes One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Personnel Changes One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ $ $ $
01: 4.212 ADOPT IN-HOUSE MATERIAL GENERATION Savings:
$50,849
Cost:
$76,500
$(-2,755) (-42,394) $(-2,028) (-377) - - $55,632 - $(-2,755)
(-42,394)
kWh
$(-2,028)
(-377)
kW-months/year
-
-
$
$55,632
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$6,711
Cost:
$26,296
$5,228 80,379 $1,345 250 $138 - - - $5,228
80,379
kWh
$1,345
250
kW-months/year
$138
-
$
-
-
$
03: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$3,403
Cost:
$10,178
$3,297 50,726 $106 20 - - - - $3,297
50,726
kWh
$106
20
kW-months/year
-
-
$
-
-
$
04: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$808
Cost:
$25
- - - - - - $808 - -
-
kWh
-
-
kW-months/year
-
-
$
$808
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$469
Cost:
$525
$368 5,651 $84 16 $17 - - - $368
5,651
kWh
$84
16
kW-months/year
$17
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$62,240
Cost:
$113,524
$6,138 94,362 $(-493) (-92) $155 - $56,440 - $6,138
94,362
kWh
$(-493)
(-92)
kW-months/year
$155
-
$
$56,440
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Personnel Changes One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Personnel Changes One-time Revenue or Avoided Cost