Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nebraska–Lincoln |
---|---|
Assessment Year | 2023 |
Principal Product | Roof Trusses |
NAICS | 321918 - Other Millwork (including Flooring) |
SIC | 2439 - Structural Wood Members, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 290,000 |
Annual Production | 12,500 Thousand Feet |
Production Hrs. Annual | 5,250 |
Location (State) | NE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $51,742 | 1,973,293 | kWh | $0.03 |
Electricity Demand | $76,464 | 4,468 | kW-months/year | $17.11 |
Electricity Fees | $10,492 | - | $ | - |
Natural Gas | $177,671 | 13,306 | MMBtu | $13.35 |
TOTAL ENERGY COSTS | $316,369 | |||
RECOMMENDED SAVINGS* | $46,712 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $45,989 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $28,330 Cost: $57,285 |
$(-479) | (-18,270) | $(-1,191) | (-70) | - | - | - | - | $30,000 | - |
$(-479) (-18,270) kWh |
$(-1,191) (-70) kW-months/year |
- - $ |
- - $ |
$30,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $16,289 Cost: $11,473 |
$6,534 | 249,375 | $9,755 | 570 | - | - | - | - | - | - |
$6,534 249,375 kWh |
$9,755 570 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,370 Cost: $1,500 |
$1,726 | 65,888 | - | - | $(-256) | - | $(-100) | - | - | - |
$1,726 65,888 kWh |
- - kW-months/year |
$(-256) - $ |
$(-100) - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $507 Cost: $1,064 |
$105 | 3,994 | $94 | 6 | $308 | - | - | - | - | - |
$105 3,994 kWh |
$94 6 kW-months/year |
$308 - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $216 Cost: $128 |
$216 | 8,245 | - | - | - | - | - | - | - | - |
$216 8,245 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $46,712 Cost: $71,450 |
$8,102 | 309,232 | $8,658 | 506 | $52 | - | $(-100) | - | $30,000 | - | $8,102 309,232 kWh |
$8,658 506 kW-months/year |
$52 - $ |
$(-100) - $ |
$30,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $45,989 Cost: $70,258 |
$7,781 | 296,993 | $8,564 | 500 | $(-256) | - | $(-100) | - | $30,000 | - | $7,781 296,993 kWh |
$8,564 500 kW-months/year |
$(-256) - $ |
$(-100) - $ |
$30,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Increase in Production |