Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nebraska–Lincoln |
---|---|
Assessment Year | 2024 |
Principal Product | Plastic Siding |
NAICS | 326199 - All Other Plastics Product Manufacturing |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 39 |
Plant Area (Sq.Ft.) | 155,829 |
Annual Production | 9,568 Tons |
Production Hrs. Annual | 2,496 |
Location (State) | MN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $362,627 | 5,288,504 | kWh | $0.07 |
Electricity Demand | $328,607 | 26,852 | kW-months/year | $12.24 |
Electricity Fees | $1,629 | - | $ | - |
Natural Gas | $95,173 | 14,430 | MMBtu | $6.60 |
Other Gas | $12,864 | 1 | MMBtu | $12,864.00 |
TOTAL ENERGY COSTS | $819,070 | |||
RECOMMENDED SAVINGS* | $38,508 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Gas | Other Liquid (non-haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Other Gas | Other Liquid (non-haz) | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $13,785 Cost: $3,000 |
$11,016 | 159,666 | $2,768 | 226 | - | - | - | - | - | - | - | - |
$11,016 159,666 kWh |
$2,768 226 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $7,684 Cost: $3,900 |
$8,184 | 118,615 | - | - | - | - | - | - | $(-400) | - | $(-100) | - |
$8,184 118,615 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$(-400) - $ |
$(-100) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,735 Cost: $10,810 |
$2,134 | 30,926 | $787 | 64 | - | - | - | - | $1,046 | - | $3,768 | - |
$2,134 30,926 kWh |
$787 64 kW-months/year |
- - MMBtu |
- - gal |
$1,046 - $ |
$3,768 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $3,054 Cost: $2,080 |
- | - | - | - | $2,836 | 1 | $218 | 1 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,836 1 MMBtu |
$218 1 gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,556 Cost: $1,315 |
$2,556 | 37,043 | - | - | - | - | - | - | - | - | - | - |
$2,556 37,043 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,203 Cost: $120 |
$2,203 | 31,932 | - | - | - | - | - | - | - | - | - | - |
$2,203 31,932 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,210 Cost: $1,348 |
$1,210 | 17,543 | - | - | - | - | - | - | - | - | - | - |
$1,210 17,543 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $281 Cost: $422 |
$94 | 1,367 | $23 | 2 | - | - | - | - | $164 | - | - | - |
$94 1,367 kWh |
$23 2 kW-months/year |
- - MMBtu |
- - gal |
$164 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $38,508 Cost: $22,995 |
$27,397 | 397,092 | $3,578 | 292 | $2,836 | 1 | $218 | 1 | $810 | - | $3,668 | - | $27,397 397,092 kWh |
$3,578 292 kW-months/year |
$2,836 1 MMBtu |
$218 1 gal |
$810 - $ |
$3,668 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Gas | Other Liquid (non-haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Other Gas | Other Liquid (non-haz) | Personnel Changes | Ancillary Material Cost |