Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nebraska–Lincoln |
---|---|
Assessment Year | 2024 |
Principal Product | Hydraulics |
NAICS | 332912 - Fluid Power Valve and Hose Fitting Manufacturing |
SIC | 3492 - Fluid Power Valves & Hose Fittings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 65 |
Plant Area (Sq.Ft.) | 109,000 |
Annual Production | 1,040,000 Units |
Production Hrs. Annual | 2,288 |
Location (State) | NE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $54,209 | 809,088 | kWh | $0.07 |
Electricity Demand | $28,961 | 3,968 | kW-months/year | $7.30 |
Natural Gas | $32,605 | 4,557 | MMBtu | $7.16 |
Other Gas | $4,660 | 1 | MMBtu | $4,660.00 |
TOTAL ENERGY COSTS | $128,719 | |||
RECOMMENDED SAVINGS* | $111,996 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Ancillary Material Cost | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $76,412 Cost: $216,424 |
$42 | 628 | - | - | - | - | $4,325 | - | $13,795 | - | $58,250 | - |
$42 628 kWh |
- - kW-months/year |
- - Tgal |
$4,325 - $ |
$13,795 - $ |
$58,250 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4321 UPGRADE OBSOLETE EQUIPMENT |
Savings: $22,584 Cost: $145,801 |
$396 | 5,907 | - | - | - | - | $1,872 | - | $20,316 | - | - | - |
$396 5,907 kWh |
- - kW-months/year |
- - Tgal |
$1,872 - $ |
$20,316 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,009 Cost: $9,991 |
$6,992 | 104,360 | $2,770 | 380 | - | - | $247 | - | - | - | - | - |
$6,992 104,360 kWh |
$2,770 380 kW-months/year |
- - Tgal |
$247 - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $2,197 Cost: $40 |
- | - | $2,197 | 301 | - | - | - | - | - | - | - | - |
- - kWh |
$2,197 301 kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4155 METER WASTE WATER |
Savings: $794 Cost: $950 |
- | - | - | - | $794 | 74 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$794 74 Tgal |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $111,996 Cost: $373,206 |
$7,430 | 110,895 | $4,967 | 681 | $794 | 74 | $6,444 | - | $34,111 | - | $58,250 | - | $7,430 110,895 kWh |
$4,967 681 kW-months/year |
$794 74 Tgal |
$6,444 - $ |
$34,111 - $ |
$58,250 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Ancillary Material Cost | Increase in Production |