Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of North Texas
Assessment Year 2023
Principal Product metal stamping products
NAICS 336370 - Motor Vehicle Metal Stamping
SIC 3469 - Metal Stampings, Nec
Sales $10,000,000-$50,000,000
# of Employees 100
Plant Area (Sq.Ft.) 80,000
Annual Production 16,594,601 Units
Production Hrs. Annual 5,200
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $169,883 2,159,800 kWh $0.08
Electricity Demand $66,666 6,666 kW-months/year $10.00
Electricity Fees $2,400 - $ -
Natural Gas $2,328 153 MMBtu $15.20
TOTAL ENERGY COSTS $241,278
RECOMMENDED SAVINGS* $136,151 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $25,455
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Personnel Changes Electricity Usage Electricity Demand Personnel Changes
$ kWh $ kW-months/year $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$9,414
Cost:
$5,801
$7,265 93,137 $2,149 215 - - $7,265
93,137
kWh
$2,149
215
kW-months/year
-
-
$
02: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$14,389
Cost:
$21,853
- - $14,389 1,439 - - -
-
kWh
$14,389
1,439
kW-months/year
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,026
Cost:
$2,499
$599 7,679 $427 43 - - $599
7,679
kWh
$427
43
kW-months/year
-
-
$
04: 2.6232 INSTALL SET-BACK TIMERS Savings:
$1,504
Cost:
-
$1,504 19,284 - - - - $1,504
19,284
kWh
-
-
kW-months/year
-
-
$
05: 3.1161 ELIMINATE/REDUCE AN OPERATION Savings:
$9,631
Cost:
-
$7,432 95,280 $2,199 220 - - $7,432
95,280
kWh
$2,199
220
kW-months/year
-
-
$
06: 4.446 AUTOMATE FINISHING PROCESS Savings:
$96,307
Cost:
$111,000
- - - - $96,307 - -
-
kWh
-
-
kW-months/year
$96,307
-
$
07: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD Savings:
$3,880
Cost:
$7,474
$2,240 28,718 $1,640 164 - - $2,240
28,718
kWh
$1,640
164
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$136,151
Cost:
$148,627
$19,040 244,098 $20,805 2,081 $96,307 - $19,040
244,098
kWh
$20,805
2,081
kW-months/year
$96,307
-
$
TOTAL IMPLEMENTED Savings:
$25,455
Cost:
$15,774
$19,040 244,098 $6,415 642 - - $19,040
244,098
kWh
$6,415
642
kW-months/year
-
-
$
Savings