Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nevada |
---|---|
Assessment Year | 1996 |
Principal Product | Aluminum Pistons |
NAICS | n/a |
SIC | 3592 - Carburetors, Pistons, Rings, Valves |
Sales | $10,000,000-$50,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 116,000 |
Annual Production | 3,000,000 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | NV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $177,658 | 3,979,484 | kWh | $0.04 |
Electricity Demand | $63,586 | 8,132 | kW-months/year | $7.82 |
Electricity Fees | $12,856 | - | $ | - |
Natural Gas | $59,446 | 48,502 | MMBtu | $1.23 |
TOTAL ENERGY COSTS | $323,146 | |||
RECOMMENDED SAVINGS* | $26,436 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $9,674 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,776 Cost: $302 |
$1,363 | 30,481 | $413 | 423 | - | - | - | - | - | - |
$1,363 30,481 kWh |
$413 423 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,192 Cost: $310 |
$2,192 | 49,238 | - | - | - | - | - | - | - | - |
$2,192 49,238 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,194 Cost: $300 |
$1,194 | 29,601 | - | - | - | - | - | - | - | - |
$1,194 29,601 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $857 Cost: $1,625 |
- | - | - | - | - | - | $857 | 129 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$857 129 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $706 Cost: $25 |
$668 | 22,567 | $38 | 43 | - | - | - | - | - | - |
$668 22,567 kWh |
$38 43 kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $2,604 Cost: $9,740 |
- | - | - | - | $2,604 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,604 - $ |
- - MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER |
Savings: $598 Cost: $1,400 |
- | - | - | - | - | - | $598 | 227 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$598 227 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $3,287 Cost: $878 |
- | - | - | - | - | - | $3,287 | 1,248 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$3,287 1,248 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $3,417 Cost: $1,504 |
- | - | - | - | - | - | $3,417 | 551 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$3,417 551 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7291 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS |
Savings: $205 Cost: $340 |
- | - | - | - | - | - | $205 | 78 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$205 78 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.2447 HEAT WATER WITH EXHAUST HEAT |
Savings: $9,600 Cost: $1,000 |
- | - | - | - | - | - | - | - | $9,600 | 48,000 |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$9,600 48,000 Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $26,436 Cost: $17,424 |
$5,417 | 131,887 | $451 | 466 | $2,604 | - | $8,364 | 2,233 | $9,600 | 48,000 | $5,417 131,887 kWh |
$451 466 kW-months/year |
$2,604 - $ |
$8,364 2,233 MMBtu |
$9,600 48,000 Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $9,674 Cost: $2,984 |
$2,557 | 60,082 | $413 | 423 | - | - | $6,704 | 1,799 | - | - | $2,557 60,082 kWh |
$413 423 kW-months/year |
- - $ |
$6,704 1,799 MMBtu |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal |