Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nevada |
---|---|
Assessment Year | 1996 |
Principal Product | Wire Fencing |
NAICS | n/a |
SIC | 3496 - Misc. Fabricated Wire Products |
Sales | $10,000,000-$50,000,000 |
# of Employees | 57 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 14,000 Tons |
Production Hrs. Annual | 6,032 |
Location (State) | NV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $103,433 | 2,271,981 | kWh | $0.05 |
Electricity Demand | $49,310 | 10,535 | kW-months/year | $4.68 |
Electricity Fees | $3,326 | - | $ | - |
Natural Gas | $105,036 | 21,937 | MMBtu | $4.79 |
TOTAL ENERGY COSTS | $261,105 | |||
RECOMMENDED SAVINGS* | $38,375 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $7,061 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $235 Cost: $100 |
$235 | 5,275 | - | - | - | - | - | - | - | - |
$235 5,275 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $678 Cost: $100 |
$678 | 14,947 | - | - | - | - | - | - | - | - |
$678 14,947 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER |
Savings: $1,603 Cost: $640 |
$1,603 | 100,234 | - | - | - | - | - | - | - | - |
$1,603 100,234 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $1,737 Cost: $3,250 |
- | - | - | - | - | - | $1,737 | 402 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$1,737 402 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,122 Cost: $246 |
$457 | 7,913 | $665 | 72 | - | - | - | - | - | - |
$457 7,913 kWh |
$665 72 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $114 Cost: $114 |
$100 | 1,172 | $14 | 2 | - | - | - | - | - | - |
$100 1,172 kWh |
$14 2 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $1,686 Cost: $3,960 |
- | - | - | - | $1,686 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,686 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.212 ADOPT IN-HOUSE MATERIAL GENERATION |
Savings: $31,200 Cost: $2,000 |
- | - | - | - | - | - | - | - | $31,200 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$31,200 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $38,375 Cost: $10,410 |
$3,073 | 129,541 | $679 | 74 | $1,686 | - | $1,737 | 402 | $31,200 | - | $3,073 129,541 kWh |
$679 74 kW-months/year |
$1,686 - $ |
$1,737 402 MMBtu |
$31,200 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $7,061 Cost: $8,296 |
$2,973 | 128,369 | $665 | 72 | $1,686 | - | $1,737 | 402 | - | - | $2,973 128,369 kWh |
$665 72 kW-months/year |
$1,686 - $ |
$1,737 402 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes |