Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nevada |
---|---|
Assessment Year | 1998 |
Principal Product | Asphalt & Concrete Aggregates |
NAICS | n/a |
SIC | 2951 - Asphalt Paving Mixtures And Blocks |
Sales | $10,000,000-$50,000,000 |
# of Employees | 75 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 3,500,000 Tons |
Production Hrs. Annual | 4,653 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $514,814 | 9,847,304 | kWh | $0.05 |
Electricity Demand | $325,103 | 45,330 | kW-months/year | $7.17 |
Electricity Fees | $29,371 | - | $ | - |
Natural Gas | $341,499 | 137,653 | MMBtu | $2.48 |
TOTAL ENERGY COSTS | $1,211,398 | |||
RECOMMENDED SAVINGS* | $496,910 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $215 Cost: $58 |
$209 | 4,103 | - | - | $6 | - | - | - | - | - |
$209 4,103 kWh |
- - kW-months/year |
$6 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $768 Cost: $661 |
$746 | 14,361 | - | - | $22 | - | - | - | - | - |
$746 14,361 kWh |
- - kW-months/year |
$22 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2427 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS |
Savings: $9,263 Cost: $30,000 |
- | - | - | - | - | - | $9,263 | 3,735 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$9,263 3,735 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $289 Cost: $416 |
- | - | - | - | - | - | $289 | 116 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$289 116 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,645 Cost: $4,179 |
$2,046 | 39,273 | $527 | 74 | $72 | - | - | - | - | - |
$2,046 39,273 kWh |
$527 74 kW-months/year |
$72 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $522 Cost: $50 |
$507 | 9,672 | - | - | $15 | - | - | - | - | - |
$507 9,672 kWh |
- - kW-months/year |
$15 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $5,436 Cost: $175 |
$5,284 | 101,114 | - | - | $152 | - | - | - | - | - |
$5,284 101,114 kWh |
- - kW-months/year |
$152 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.425 ELIMINATE/REDUCE REDUNDANT INSPECTIONS |
Savings: $477,397 Cost: $1,400,000 |
- | - | - | - | - | - | - | - | $477,397 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$477,397 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4151 MINIMIZE WATER USAGE |
Savings: $375 Cost: $800 |
$141 | 2,638 | $224 | 31 | $10 | - | - | - | - | - |
$141 2,638 kWh |
$224 31 kW-months/year |
$10 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $496,910 Cost: $1,436,339 |
$8,933 | 171,161 | $751 | 105 | $277 | - | $9,552 | 3,851 | $477,397 | - | $8,933 171,161 kWh |
$751 105 kW-months/year |
$277 - $ |
$9,552 3,851 MMBtu |
$477,397 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes |