Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nevada |
---|---|
Assessment Year | 1998 |
Principal Product | Industrial Absorbent |
NAICS | n/a |
SIC | 3295 - Minerals, Ground Or Treated |
Sales | $5,000,000-$10,000,000 |
# of Employees | 55 |
Plant Area (Sq.Ft.) | 80,000 |
Annual Production | 52,440 Tons |
Production Hrs. Annual | 6,240 |
Location (State) | NV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $92,734 | 2,214,537 | kWh | $0.04 |
Electricity Demand | $48,921 | 5,653 | kW-months/year | $8.65 |
Electricity Fees | $791 | - | $ | - |
Fuel Oil #2 | $27,728 | 16,878 | MMBtu | $1.64 |
TOTAL ENERGY COSTS | $170,174 | |||
RECOMMENDED SAVINGS* | $439,969 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $75,705 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $1,772 Cost: $2,333 |
- | - | - | - | $1,772 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,772 - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $3,392 Cost: $1,226 |
$2,441 | 58,324 | $999 | 116 | $(-48) | - | - | - | - | - |
$2,441 58,324 kWh |
$999 116 kW-months/year |
$(-48) - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $4,937 Cost: $10,398 |
$3,541 | 84,701 | $1,465 | 170 | $(-69) | - | - | - | - | - |
$3,541 84,701 kWh |
$1,465 170 kW-months/year |
$(-69) - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.446 AUTOMATE FINISHING PROCESS |
Savings: $68,996 Cost: $19,100 |
$(-184) | (-4,396) | $565 | (-66) | $(-25) | - | - | - | $68,640 | - |
$(-184) (-4,396) kWh |
$565 (-66) kW-months/year |
$(-25) - $ |
- - lb |
$68,640 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.441 INSTALL AUTOMATIC PACKING EQUIPMENT |
Savings: $358,805 Cost: $198,720 |
$(-655) | (-15,533) | $(-10) | (-1) | $7 | - | - | - | $359,463 | - |
$(-655) (-15,533) kWh |
$(-10) (-1) kW-months/year |
$7 - $ |
- - lb |
$359,463 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $2,067 Cost: - |
- | - | - | - | - | - | $2,067 | 52,000 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$2,067 52,000 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $439,969 Cost: $231,777 |
$5,143 | 123,096 | $3,019 | 219 | $1,637 | - | $2,067 | 52,000 | $428,103 | - | $5,143 123,096 kWh |
$3,019 219 kW-months/year |
$1,637 - $ |
$2,067 52,000 lb |
$428,103 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $75,705 Cost: $31,831 |
$3,357 | 80,305 | $2,030 | 104 | $1,678 | - | - | - | $68,640 | - | $3,357 80,305 kWh |
$2,030 104 kW-months/year |
$1,678 - $ |
- - lb |
$68,640 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | Personnel Changes |