Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nevada |
---|---|
Assessment Year | 1998 |
Principal Product | Liquid Sodium Cyanide |
NAICS | n/a |
SIC | 2819 - Industrial Inorganic Chemicals, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 28 |
Plant Area (Sq.Ft.) | 16,700 |
Annual Production | 60,000,000 Tons |
Production Hrs. Annual | 8,064 |
Location (State) | NV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $400,968 | 9,488,277 | kWh | $0.04 |
Electricity Demand | $136,030 | 16,961 | kW-months/year | $8.02 |
Electricity Fees | $7,360 | - | $ | - |
Natural Gas | $1,788,061 | 679,923 | MMBtu | $2.63 |
TOTAL ENERGY COSTS | $2,332,419 | |||
RECOMMENDED SAVINGS* | $65,567 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $63,383 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $60,884 Cost: $48,211 |
$52,652 | 1,245,897 | $8,538 | 1,075 | $(-306) | - |
$52,652 1,245,897 kWh |
$8,538 1,075 kW-months/year |
$(-306) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $928 Cost: $252 |
$802 | 19,050 | $130 | 16 | $(-4) | - |
$802 19,050 kWh |
$130 16 kW-months/year |
$(-4) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $2,499 Cost: - |
$2,160 | 50,996 | $352 | 44 | $(-13) | - |
$2,160 50,996 kWh |
$352 44 kW-months/year |
$(-13) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,256 Cost: $4,009 |
$1,087 | 25,791 | $176 | 22 | $(-7) | - |
$1,087 25,791 kWh |
$176 22 kW-months/year |
$(-7) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $65,567 Cost: $52,472 |
$56,701 | 1,341,734 | $9,196 | 1,157 | $(-330) | - | $56,701 1,341,734 kWh |
$9,196 1,157 kW-months/year |
$(-330) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $63,383 Cost: $48,211 |
$54,812 | 1,296,893 | $8,890 | 1,119 | $(-319) | - | $54,812 1,296,893 kWh |
$8,890 1,119 kW-months/year |
$(-319) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Electricity Usage | Electricity Demand | Electricity Fees |