Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nevada |
---|---|
Assessment Year | 1999 |
Principal Product | Commercial Printing, Lithographic |
NAICS | n/a |
SIC | 2752 - Commercial Printing, Lithographic |
Sales | $1,000,000-$5,000,000 |
# of Employees | 35 |
Plant Area (Sq.Ft.) | 18,200 |
Annual Production | 125,000 Pounds |
Production Hrs. Annual | 4,420 |
Location (State) | NV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $22,442 | 537,808 | kWh | $0.04 |
Electricity Demand | $21,873 | 2,357 | kW-months/year | $9.28 |
Electricity Fees | $1,498 | - | $ | - |
Natural Gas | $9,324 | 1,774 | MMBtu | $5.26 |
TOTAL ENERGY COSTS | $55,137 | |||
RECOMMENDED SAVINGS* | $530,756 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes | Increase in Production | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,202 Cost: $4,519 |
$1,217 | 29,308 | $942 | 102 | $43 | - | - | - | - | - | - | - | - | - |
$1,217 29,308 kWh |
$942 102 kW-months/year |
$43 - $ |
- - MMBtu |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $2,445 Cost: $4,015 |
- | - | - | - | - | - | $2,445 | 474 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$2,445 474 MMBtu |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $1,829 Cost: $800 |
$(-70) | (-1,758) | $(-31) | (-3) | $(-2) | - | $1,932 | 375 | - | - | - | - | - | - |
$(-70) (-1,758) kWh |
$(-31) (-3) kW-months/year |
$(-2) - $ |
$1,932 375 MMBtu |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $331 Cost: $170 |
- | - | - | - | - | - | - | - | $331 | 151,200 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$331 151,200 Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.131 MODIFY PROCESS TO REDUCE MATERIAL USE/COST |
Savings: $500,000 Cost: $3,070,000 |
- | - | - | - | - | - | - | - | - | - | - | - | $500,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
$500,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $23,949 Cost: $164,000 |
- | - | - | - | - | - | - | - | - | - | $3,949 | - | $20,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
$3,949 - $ |
$20,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $530,756 Cost: $3,243,504 |
$1,147 | 27,550 | $911 | 99 | $41 | - | $4,377 | 849 | $331 | 151,200 | $3,949 | - | $520,000 | - | $1,147 27,550 kWh |
$911 99 kW-months/year |
$41 - $ |
$4,377 849 MMBtu |
$331 151,200 Tgal |
$3,949 - $ |
$520,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - Tgal |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | Tgal | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes | Increase in Production | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Water Disposal | Personnel Changes | Increase in Production |