Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nevada |
---|---|
Assessment Year | 1999 |
Principal Product | Steel Joist |
NAICS | n/a |
SIC | 3441 - Fabricated Structural Metal |
Sales | $10,000,000-$50,000,000 |
# of Employees | 320 |
Plant Area (Sq.Ft.) | 137,500 |
Annual Production | 40,000 Tons |
Production Hrs. Annual | 4,420 |
Location (State) | NV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $146,478 | 3,425,850 | kWh | $0.04 |
Electricity Demand | $61,197 | 7,625 | kW-months/year | $8.03 |
Electricity Fees | $6,113 | - | $ | - |
Natural Gas | $66,103 | 11,206 | MMBtu | $5.90 |
TOTAL ENERGY COSTS | $279,891 | |||
RECOMMENDED SAVINGS* | $65,559 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $855 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $5,222 Cost: $5,533 |
$3,239 | 52,462 | - | - | $1,983 | - | - | - |
$3,239 52,462 kWh |
- - kW-months/year |
$1,983 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,525 Cost: $344 |
$1,010 | 23,740 | $515 | 64 | - | - | - | - |
$1,010 23,740 kWh |
$515 64 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $855 Cost: $150 |
$534 | 12,603 | $321 | 40 | - | - | - | - |
$534 12,603 kWh |
$321 40 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $18,506 Cost: - |
$18,506 | 432,884 | - | - | - | - | - | - |
$18,506 432,884 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $25,801 Cost: $62,350 |
$18,958 | 443,435 | $6,843 | 853 | - | - | - | - |
$18,958 443,435 kWh |
$6,843 853 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS |
Savings: $13,650 Cost: $20,000 |
- | - | - | - | - | - | $13,650 | - |
- - kWh |
- - kW-months/year |
- - $ |
$13,650 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $65,559 Cost: $88,377 |
$42,247 | 965,124 | $7,679 | 957 | $1,983 | - | $13,650 | - | $42,247 965,124 kWh |
$7,679 957 kW-months/year |
$1,983 - $ |
$13,650 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $855 Cost: $150 |
$534 | 12,603 | $321 | 40 | - | - | - | - | $534 12,603 kWh |
$321 40 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes |