Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Nevada |
---|---|
Assessment Year | 1999 |
Principal Product | Seals and Gaskets |
NAICS | n/a |
SIC | 3053 - Gaskets, Packing And Sealing Devices |
Sales | $5,000,000-$10,000,000 |
# of Employees | 70 |
Plant Area (Sq.Ft.) | 55,000 |
Annual Production | 400,000 Pieces |
Production Hrs. Annual | 2,412 |
Location (State) | NV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $16,836 | 403,283 | kWh | $0.04 |
Electricity Demand | $13,558 | 1,461 | kW-months/year | $9.28 |
Electricity Fees | $1,239 | - | $ | - |
Natural Gas | $11,391 | 2,175 | MMBtu | $5.24 |
TOTAL ENERGY COSTS | $43,024 | |||
RECOMMENDED SAVINGS* | $12,947 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,278 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $314 Cost: $661 |
$236 | 5,569 | $72 | 8 | $6 | - | - | - | - | - |
$236 5,569 kWh |
$72 8 kW-months/year |
$6 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $852 Cost: $2,475 |
$391 | 9,379 | $444 | 48 | $17 | - | - | - | - | - |
$391 9,379 kWh |
$444 48 kW-months/year |
$17 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,112 Cost: $7,124 |
$975 | 23,447 | $1,096 | 118 | $41 | - | - | - | - | - |
$975 23,447 kWh |
$1,096 118 kW-months/year |
$41 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $3,838 Cost: $3,838 |
$(-264) | (-6,448) | $(-82) | (-9) | $(-7) | - | $4,191 | 813 | - | - |
$(-264) (-6,448) kWh |
$(-82) (-9) kW-months/year |
$(-7) - $ |
$4,191 813 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $3,860 Cost: $1,350 |
$653 | 8,206 | - | - | - | - | $3,207 | 622 | - | - |
$653 8,206 kWh |
- - kW-months/year |
- - $ |
$3,207 622 MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $1,971 Cost: $970 |
- | - | - | - | - | - | - | - | $1,971 | 67,200 |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
$1,971 67,200 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $12,947 Cost: $16,418 |
$1,991 | 40,153 | $1,530 | 165 | $57 | - | $7,398 | 1,435 | $1,971 | 67,200 | $1,991 40,153 kWh |
$1,530 165 kW-months/year |
$57 - $ |
$7,398 1,435 MMBtu |
$1,971 67,200 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,278 Cost: $10,260 |
$1,602 | 38,395 | $1,612 | 174 | $64 | - | - | - | - | - | $1,602 38,395 kWh |
$1,612 174 kW-months/year |
$64 - $ |
- - MMBtu |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Solid Waste (non-haz) |