Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Old Dominion Univ. |
---|---|
Assessment Year | 1997 |
Principal Product | Ribbon |
NAICS | n/a |
SIC | 2396 - Automotive And Apparel Trimmings |
Sales | $5,000,000-$10,000,000 |
# of Employees | 80 |
Plant Area (Sq.Ft.) | 28,000 |
Annual Production | 9,000,000 Thousand Feet |
Production Hrs. Annual | 2,125 |
Location (State) | VA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $15,883 | 310,082 | kWh | $0.05 |
Electricity Demand | $5,946 | 1,058 | kW-months/year | $5.62 |
Electricity Fees | $2,981 | - | $ | - |
Natural Gas | $11,543 | 1,747 | MMBtu | $6.61 |
TOTAL ENERGY COSTS | $40,956 | |||
RECOMMENDED SAVINGS* | $759,385 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Raw Material | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Raw Material | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,491 Cost: $5,176 |
$949 | 18,464 | $1,542 | 105 | - | - | - | - | - | - | - | - | - | - | - | - |
$949 18,464 kWh |
$1,542 105 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6214 SHUT OFF PILOTS IN STANDBY EQUIPMENT |
Savings: $222 Cost: - |
- | - | - | - | $222 | 45 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$222 45 MMBtu |
- - lb |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS |
Savings: $485 Cost: - |
- | - | - | - | - | - | $485 | 4,411 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$485 4,411 lb |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.1181 ELIMINATE A BY-PRODUCT |
Savings: $204,312 Cost: $6,350 |
- | - | - | - | - | - | - | - | - | - | $54,312 | - | - | - | $150,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
$54,312 - $ |
- - $ |
$150,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.322 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL |
Savings: $551,875 Cost: $51,389 |
- | - | - | - | - | - | - | - | $15,625 | - | - | - | $536,250 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$15,625 - $ |
- - $ |
$536,250 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $759,385 Cost: $62,915 |
$949 | 18,464 | $1,542 | 105 | $222 | 45 | $485 | 4,411 | $15,625 | - | $54,312 | - | $536,250 | - | $150,000 | - | $949 18,464 kWh |
$1,542 105 kW-months/year |
$222 45 MMBtu |
$485 4,411 lb |
$15,625 - $ |
$54,312 - $ |
$536,250 - $ |
$150,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Raw Material | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Primary Raw Material | By-product Production |